Plan Review Notes
Plan Review Notes For Permit 07060573
Permit Number 07060573
Review Stop B
Sequence Number 1
Notes
Date Text
2007-07-06 12:14:34****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)PROVIDE JUSTIFICATION FOR DESIGN PRESSURE OF -31
 FOR OPENING 3, FBC R TABLE 301.2.2(2).THIS OPENING,
 96X101, IS A TOTAL OF 9696 SQUARE INCHES, 67.33 SQUARE
 FEET.THE TABLE REQUIRES -34.6 FOR A 50 SQUARE FOOT
 OPENING, -33 FOR A 100 SQUARE FOOT OPENING.IN ORDER
 TO USE ASCE7-02 FOR DESIGN PRESSURES, ENGINEERING IS
 REQUIRED.CHECK ALL OPENINGS.PLEASE CONTACT ME IF
 YOU NEED ASSISTANCE IN DETERMINING DESIGN PRESSURES.
  