Plan Review Notes
Plan Review Notes For Permit 07060347
Permit Number 07060347
Review Stop B
Sequence Number 1
Notes
Date Text
2007-07-11 10:16:44BUILDING REVIEW CHECKLIST:
 1-A) SINGLE HUNG WINDOWS NOA 01-0516.10 SUBMITTED
 EXPIRED ON 09/30/2006. NEED TO PROVIDE CURRENT NOA.
  
 B) PROVIDE TWO COPIES.
  
 C) SPECIFY EXISTING WINDOW OPENING SIZEAND TYPE OF
 EXISTING WINDOW TO VERIFY COMPLIANCE WITH EGRESS
 REQUIREMENTS.
  
 2- IF WINDOWS TO BE REPLACED DON'T HAVE IMPACT GLAZING,
 THEN COMPLETE INFORMATION FOR STORM SHUTTERS NEED TO BE
 PROVIDED. PROVIDE COMPLETE INSTALLATION SCHEDULE. SEE
 ATTACHED COPY.ALSO,CLEARLY MARK ON SHUTTER DRAWINGS
 SPECIFIC MOUNTING CONDITIONS ANDSPECIFIC ANCHORTYPE
 AND SPACING TO BE USED ACCORDING TO THE EDGE DISTANCE,
 DESIGN PRESSURES, CONNECTION TYPE AND SPECIFIC
 STRUCTURE TO BE ATTACHED TO (CONCRETE BLOCK).SEC.
 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 3- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 13-600.1.C.2OF FBC 2004.
 ***NOTE: MAKE SURE 2006 REVISED FORM IS USED.
  
 4- A/C CHANGE OUTS TO BE DONE UNDER A SEPARATE PERMIT.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712