Plan Review Notes
Plan Review Notes For Permit 07051146
Permit Number 07051146
Review Stop B
Sequence Number 2
Notes
Date Text
2007-06-14 14:05:28****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
  
 1.)ZONE 3 HAS A DESIGN PRESSURE REQUIREMENT OF -83.1
 IF IT IS IN EXPOSURE B; SEE FBC TABLE 1609.6.2.1(2).
 THE ASSEMBLY HAS A LIMITATION OF -75, NO ENHANCED
 FASTENING ALLOWED PER SYSTEM LIMITATION #1.
  
 2.)PROVIDE A SITE PLAN SHOWING BUILDING LOCATION.
 SEE FBC1609.6.2.1(2), DEFINITION OF EXPOSURE C.IF
 THIS BUILDING IS EXPOSURE C, DESIGN PRESSURE OF -100.56
 IS REQUIRED FOR ZONE 3.
  