Plan Review Notes
Plan Review Notes For Permit 07051105
Permit Number 07051105
Review Stop B
Sequence Number 1
Notes
Date Text
2007-07-02 18:06:06PROJECT: 800 45TH STREET
  
 PROJECT WORK SCOPE: REMOVE EXISTING SCREEN ENCLOSURE/
 CONSTRUCT BEDROOM & BATH
  
 PLAN REVIEW: 2004 FLORIDA EXISTING BUILDING CODE AND
 FLORIDA BUILDING CODE WITH 2006 REVISIONS.
  
 STATUS: DENIED
  
  
 PLAN REVIEW COMMENTS:
  
 1)105.8 NOTICE OF COMMENCEMENT.
 AS PER SECTION 713.135, FLORIDA STATUTES, WHEN ANY
 PERSON APPLIES FOR A BUILDING PERMIT, THE AUTHORITY
 ISSUING SUCH PERMIT SHALL PRINT ON THE FACE OF EACH
 PERMIT CARD IN NO LESS THAN 18-POINT, CAPITALIZED,
 BOLDFACED TYPE:?WARNING TO OWNER: YOUR FAILURE TO
 RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
 PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU
 INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR
 AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
 COMMENCEMENT.?
  
 2) INITIAL AND SIGN THE OWNER BUILDER INFORMATION
 FORM.
  
 3) PROVIDE SUPPORTING DOCUMENTATION VERIFYING THE
 EXISTING SIZE OF THE MONOLITHIC FOUNDATION AND
 REINFORCING STEEL PLACEMENT. INDICATE CONCRETE
 SPECIFICATIONS OF NEW FLOOR SLAB OVERLAY.
  
 4) PLEASE PROVIDE PRODUCT APPROVALS AND SPECIFICATIONS
 FOR ALL MECHANICAL CONNECTORS AND ANCHORS TO BE
 UTILIZED.
  
 5) PLEASE INDICATE SPECIES AND GRADE OF LUMBER.
  
 6) PROVIDE THE FOLLOWING INFORMATION:
  
 A) WINDOW TYPE AND GLAZING SPECS.
 B) DOOR SPECIFICATIONS/ DESIGN PRESSURE.
 C) NEW DOOR AT PLAYROOM SHOWS A WINDOW. THE
 SUBMITTED PRODUCT APPROVAL DOES NOT REFLECT THE SAME.
 D) REQUIRE 2 COPIES OF DOOR AND WINDOW PRODUCT
 APPROVALS.
  
  
 7) THE OBS WINDOW AT THE BATHROOM SHALL BE SAFETY
 TEMPERED GLAZING AS PER THE FOLLOWING:
  
 2406.3 HAZARDOUS LOCATIONS.
 THE FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS
 LOCATIONS REQUIRING SAFETY GLAZING MATERIALS:
  
 5. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS,
 WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS.
 GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING
 THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE
 GLAZING IS LESS THAN 60 INCHES (1524 MM) ABOVE A
 STANDING SURFACE.
  
 8) PLEASE SHOW ALL EXTERIOR ELEVATIONS.
  
 9) SMOKE ALARMS SHALL BE INSTALLED PER THE FOLLOWING:
  
 604.4.3SMOKE ALARMS.
 INDIVIDUAL SLEEPING UNITS AND INDIVIDUAL DWELLING UNITS
 IN ANY WORK AREA IN GROUP R-1, R-2, R-3, R-4, AND I-1
 OCCUPANCIES SHALL BE PROVIDED WITH SMOKE ALARMS IN
 ACCORDANCE WITH THE FLORIDA FIRE PREVENTION CODE.
 EXCEPTION: INTERCONNECTION OF SMOKE ALARMS OUTSIDE OF
 THE REHABILITATION WORK AREA SHALL NOT BE REQUIRED.
  
 10) PLEASE SHOW AN INTERIOR WALL FRAMING SECTION.
  
 11) ALL OPENINGS SHALL BE PROTECTED. PLEASE PROVIDE
 SHUTTER PRODUCT APPROVALS.
  
 1609.1.4 PROTECTION OF OPENINGS.
 IN WIND-BORNE DEBRIS REGIONS, EXTERIOR GLAZING THAT
 RECEIVES POSITIVE PRESSURE IN THE LOWER 60 FEET (18.3
 M) IN BUILDINGS SHALL BE ASSUMED TO BE OPENINGS AND THE
 BALANCE OF GLAZED OPENINGS IN THE REST OF THE BUILDING
 SHALL BE ASSUMED TO BE ZERO UNLESS SUCH GLAZING THAT
 RECEIVES POSITIVE PRESSURE IS IMPACT RESISTANT OR
 PROTECTED WITH AN IMPACT RESISTANT COVERING MEETING THE
 REQUIREMENTS OF SSTD 12, ASTM E 1886 AND ASTM E 1996,
 ANSI/DASMA 115 (FOR GARAGE DOORS AND ROLLING DOORS) OR
 MIAMI-DADE TAS 201, 202 AND 203 OR AAMA 506 REFERENCED
 THEREIN AS FOLLOWS:
 1. GLAZED OPENINGS LOCATED WITHIN 30 FEET (9.1 M) OF
 GRADE SHALL MEET THE REQUIREMENTS OF THE LARGE MISSILE
 TEST.
 2. GLAZED OPENINGS LOCATED MORE THAN 30 FEET (9.1 M)
 ABOVE GRADE SHALL MEET THE PROVISIONS OF THE SMALL
 MISSILE TEST.
 3. STORAGE SHEDS THAT ARE NOT DESIGNED FOR HUMAN
 HABITATION AND THAT HAVE A FLOOR AREA OF 720 SQUARE
 FEET (67 M2) OR LESS ARE NOT REQUIRED TO COMPLY WITH
 THE MANDATORY WINDBORNE DEBRIS IMPACT STANDARDS OF THIS
 CODE.
 4. OPENINGS IN SUNROOMS, BALCONIES OR ENCLOSED PORCHES
 CONSTRUCTED UNDER EXISTING ROOFS OR DECKS ARE NOT
 REQUIRED TO BE PROTECTED PROVIDED THE SPACES ARE
 SEPARATED FROM THE BUILDING INTERIOR BY A WALL AND ALL
 OPENINGS IN THE SEPARATING WALL ARE PROTECTED IN
 ACCORDANCE WITH SECTION 1609.1.4 ABOVE. SUCH SPACES
 SHALL BE PERMITTED TO BE DESIGNED AS EITHER PARTIALLY
 ENCLOSED OR ENCLOSED STRUCTURES.
  
 12) THE PROPOSED CONSTRUCTION VALUE APPEARS TO BE LOW
 AS PER THE MARSHAL AND SWIFT COST ESTIMATION.
  
 PLAN REVIEW: KEN CONRAD
  
 PHONE: 561.805.6666
 E-MAIL: KCONRAD@ WPB.ORG


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved