Plan Review Notes
Plan Review Notes For Permit 07051085
Permit Number 07051085
Review Stop B
Sequence Number 4
Notes
Date Text
2007-06-22 13:27:14REVISION TO CHANGE FROM ASPHALT SHINGLES TO CONCRETE
 ROOF TILE IS DENIED.
  
 1) SUBMIT A SIGNED AND SEALED LETTER FROM A FLORIDA
 LICENSED ENGINEER STATING THAT THE EXISTING ROOF
 STRUCTURE IS CAPABLE OF SUPPORTING THE PROPOSED
 CONCRETE ROOF.
  
 2) SPECIFY THE METOD OF ATTACHMENT THAT WILL BE USED TO
 INSTALL THE CONCRETE ROOF TILES. CIRCLE THE FASTENER
 TYPE OR ADHESIVE SYSTEM THAT WILL BE USED ON THE NOA.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  