2009-02-03 15:44:31 | 435 NORTHWOOD RD, |
| LOT 28/ 07050947 |
| FEB.03,2009 |
| |
| BUILDING PLAN REVIEW |
| PERMIT: 07050947 |
| ADD: 435 NORTHWOOD RD |
| CONT: KDN CONSTRUCTION SERVICES, LLC |
| TEL: (561)662-1002 |
| |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2006 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 4TH REVIEW |
| ACTION: DENIED |
| |
| 1) --- VERY IMPORTANT STATEMENT --- |
| PLEASE DO NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL |
| LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH |
| A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE |
| SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE |
| FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR |
| YOUR ANTICIPATED COOPERATION. |
| |
| 2) FL. S. S. 713.13 NOTICE OF COMMENCEMENT, TO BE FILED |
| WITH THE CLERK OF THE COURT. NOTE: 713.13(2) IF THE |
| WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS NOT |
| ACTUALLY COMMENCED WITHIN 90 DAYS AFTER THE RECORDING |
| THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) |
| THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE FL |
| CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| |
| 3-6) COMPLIED. |
| |
| 7-8) COMPLIED. THIS COMMENT DEALS WITH THE EXTERIOR |
| WALLS OF THE BUILDING AND ADDITION. SINCE THERE IS NO |
| WORK BEING COMPLETEED TO THE EXISTING BUILDING ON THE |
| EXTERIOR WALLS THIS COMMENT PERTAINS EXCLUSIVELY TO THE |
| ADDITION WALLS TABLE 601 DEALS WITH THE BUILDING |
| ELEMENTS, TABLE 602 DEALS WITH FIRE-RESISTANCE RATING |
| REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE |
| SEPERATION, THE TYPE V-B BUILDING < 5 FEET WOULD |
| REQUIRE A 1 HOUR FIRE SEPERATION, WHICH THE BLOCK WALL |
| WILL MEET THIS REQUIREMENT. |
| |
| 9-14 COMPLIED. |
| |
| 15) RESPONCE INDICATES THIS SPACE TO BE A SHELL |
| BUILDING. 1203.2 ATTIC SPACES. ENCLOSED ATTICS AND |
| ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE |
| APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF FRAMING |
| MEMBERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE |
| SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE |
| ENTRANCE OF RAIN. BLOCKING AND BRIDGING SHALL BE |
| ARRANGED SO AS NOT TO INTERFERE WITH THE MOVEMENT OF |
| AIR. A MINIMUM OF 1 INCH (25 MM) OF AIRSPACE SHALL BE |
| PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING. |
| SHEET 3 INDICATES THE USE OF 2X12'S @ 16" O.C. THE |
| PLANS DO NOT INDICATE ANY TYPE OF BLOCKING OR BRIDGING |
| FOR THE SPAN OF OVER 23'-0". |
| 2308.10.6 BLOCKING.ROOF RAFTERS AND CEILING JOISTS |
| SHALL BE SUPPORTED LATERALLY TO PREVENT ROTATION AND |
| LATERAL DISPLACEMENT IN ACCORDANCE WITH THE PROVISIONS |
| OF SECTION 2308.8.5. |
| |
| 2308.8.5 LATERAL SUPPORT. |
| FLOOR, ATTIC AND ROOF FRAMING WITH A NOMINAL |
| DEPTH-TO-THICKNESS RATIO GREATER THAN OR EQUAL TO 5:1 |
| SHALL HAVE ONE EDGE HELD IN LINE FOR THE ENTIRE SPAN. |
| WHERE THE NOMINAL DEPTH-TO-THICKNESS RATIO OF THE |
| FRAMING MEMBER EXCEEDS 6:1, THERE SHALL BE ONE LINE OF |
| BRIDGING FOR EACH 8 FEET (2438 MM) OF SPAN, UNLESS BOTH |
| EDGES OF THE MEMBER ARE HELD IN LINE. THE BRIDGING |
| SHALL CONSIST OF NOT LESS THAN 1-INCH BY 3-INCH (25 MM |
| BY 76 MM) LUMBER, DOUBLE NAILED AT EACH END, OF |
| EQUIVALENT METAL BRACING OF EQUAL RIGIDITY, FULL-DEPTH |
| SOLID BLOCKING OR OTHER APPROVED MEANS. A LINE OF |
| BRIDGING SHALL ALSO BE REQUIRED AT SUPPORTS WHERE |
| EQUIVALENT LATERAL SUPPORT IS NOT OTHERWISE PROVIDED. |
| |
| 16-27) COMPLIED. |
| |
| |
| 28) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL |
| PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND |
| A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT |
| APPLICATION PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| 29) PERMIT FEES ARE TO BE PAID AT TIME OF APPLICATION A |
| HOLD WILL BE PLACED BEFORE RESUBMITTAL .$156.06 DUE. |
| |
| 30) 21) THIS REVIEW ENERGY CALCULATIONS WERE SUBMITTED. |
| PART OF THE RESPONSE TO COMMENT NUMBER 12 INDICATED |
| THAT THE ROOF/CEILING INSULATION WAS TO BE THE |
| RESPONSIBILITY OF THE TENANT. BUT THE ENERGY CALCS CAME |
| IN AS METHOD "B" WHICH CAN BE FOR THE "SHELL BUILDING". |
| 3-101.1.6 SHELL BUILDINGS. |
| NONRESIDENTIAL BUILDINGS THAT ARE PERMITTED PRIOR TO |
| DESIGN COMPLETION OR WHICH WILL BE FINISHED IN SECTIONS |
| AT A TIME AFTER CONSTRUCTION OF THE SHELL SHALL COMPLY |
| WITH EITHER METHOD B OR C OF SUBCHAPTER 13-4 OF THE |
| CODE PRIOR TO GRANTING OF A PERMIT TO BUILD. ALL |
| ASSUMPTIONS MADE ABOUT FEATURES NOT INSTALLED UNTIL |
| LATER THAT ARE NOT ON THE BUILDING PLANS SHALL BE |
| LISTED AND APPENDED TO THE COMPLIANCE FORM SUBMITTED TO |
| THE BUILDING DEPARTMENT. UNLESS THE BUILDING IS |
| COMPLETED AS PER ALL ASSUMPTIONS MADE IN THE ORIGINAL |
| CODE COMPLIANCE SUBMITTAL, A REVISED CODE SUBMITTAL(S) |
| USING METHODS A, B OR C SHALL BE SUBMITTED WHEN |
| COMPLETION OF THE BUILDING (OR PART OF THE BUILDING) IS |
| PERMITTED. |
| |
| WITHIN THE DATAINPUT REPORT UNDER THE HEADING OF |
| ROOFING THE REPORT INDICATES THE USE OF 6" BATTS WHICH |
| WILL NEED TO BE REFLECTED WITHIN THE PLANS, THE ROOFING |
| SECTION OF THE INPUT DATA REPORT ALSO INDICATED USE OF |
| SHINGLES, THAT WILL NEED TO BE CORRECTED WITHIN THE |
| DATA INPUT REPORT. |
| |
| THE SECOND ISSUE WITH THE DATA INPUT REPORT IS THE |
| EXTERIOR BACK DOOR IS INDICATED AS A SOLID CORE 2.25 |
| INCH DOOR WHERE WHAT WAS SUBMITTED IS A 1 33/4 FOAM |
| FILLED DOOR. |
| |
| THE THIRD ITEM THAT WILL NEED TO BE REVIEWED IS THIS IS |
| FOR THE SHELL OF THE BUILDING BUT THE WALL SQUARE |
| FOOTAGE IS ONLY FOR THE ADDITION NOT THE SHELL |
| BUILDING. |
| |
| THE FOURTH ITEM IS THE FOURTH EXTERIOR WALL NOT INTHE |
| DATA INPUT REPORT IS MISSING THE GLAZED WINDOW AND |
| DOORWAY IN THE FRONT OF THE BUILDING. |
| |
| BUILDING PLAN REVIEW II |
| JIM WITMER C. B. O. |
| |
| TEL: (561)805-6715 |
| FAX: (561)659-8026 |
| E-MAIL: [email protected] |
| |