2007-06-30 14:32:14 | |
| |
| DENIED |
| |
| 1)BEFORE A PERMIT TO CONSTRUCT, MAY |
| BE ISSUED, IMPACT FEES MUST BE PAID TO |
| PALM BEACH COUNTY. THE ACTUAL PERMIT |
| SETS OF PLANS MUST BE STAMPED BY THAT |
| OFFICE, AND A COPY OF THE PAID RECEIPT |
| ATTACHED TO THE PERMIT APPLICATION. |
| PLEASE CALL (561) 233-5025 FOR MORE |
| INFORMATION. PLEASE SEE THAT THE SQUARE FOOTAGE ONLY |
| APPLIES TO ADDITION AND DOES NOT INCLUDE TWO STORY |
| GUEST HOUSE, IF COUNTY HAS EXEMPTED THIS BUILDING |
| PLEASE PROVIDE LETTER FROM THAT JURISDICTION |
| |
| 2)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC |
| (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| PER 108.3 FBC* |
| |
| 3)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON |
| SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER |
| ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE |
| ADDED TO THE PERMIT APPLICATION FEES. |
| NOTE: THE AMOUNT DUE FOR INCREASED VALUE AND STATE |
| RADON FEES IS $ 218.04 AND IS PAYABLE BEFORE FURTHER |
| REVIEWS ARE MADE. |
| |
| 4)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL |
| COMPLY WITH THE 2004 FL BLDG CODE WITH 2006 AMENDMENTS. |
| THIS APPLIES TO ARCHITECTURAL AND STRUCTURAL DRAWINGS. |
| |
| 5)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING |
| MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF |
| ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND |
| STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE |
| DRAWINGS |
| |
| 6)IN AREAS OF QUESTIONABLE SOILS AS SHOWN IN THE |
| OFFICIAL ZONING MAP OF THE CITY OF WEST PALM BEACH, 2 |
| COPIES OF A SOIL TEST REPORT SHALL BE SUBMITTED PER |
| R401.4 FBC RES. |
| |
| 7)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 |
| FBC. BE SURE THAT THEY ARE SIGNED AND |
| DATED BY PREPARER AND OWNER/AGENT PRIOR |
| TO SUBMITTAL. SEPARATE ENERGY CALC'S ARE REQUIRED FOR |
| THE ADDITION AND THE NEW GUEST HOUSE |
| |
| 8)SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT |
| COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR |
| BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND |
| APPROVED BY THE DESIGNER OF RECORD |
| |
| 9)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF |
| EACH PRODUCT APPROVAL THAT |
| IS RELEVANT PER 9B-72. THESE SHOULD INCLUDE THE FLORIDA |
| STATE APPROVAL COVER PAGES, AND THE PRODUCT NOA THAT |
| LISTS THE SYSTEM COMPONENTS/ FASTENER LIST PAGES, THE |
| PAGES WITH THE CHOSEN ASSEMBLY/ SYSTEM TO BE USED AND |
| THE GENERAL LIMITATIONS PAGE. ALL CAN BE FOUND ON |
| WWW.FLORIDABUILDING.ORG |
| |
| 10)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE |
| 9B-72 (PRODUCT APPROVALS) SHALL BE REVIEWED AND |
| APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR TO |
| SUBMITTAL FOR JURISDICTIONAL APPROVAL PER 106.3.3 FBC* |
| |
| |
| 11)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA |
| STATE PRODUCT APPROVAL COVER |
| SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON |
| WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT |
| SUBMITTED APPLICATIONS WILL BE DENIED |
| |
| 12)PLEASE CLARIFY FOUNDATION SCHEDULE ON S/1 THEIR |
| ARE 2 F30 FOOTING MARKS |
| |
| 13)PLEASE CLARIFY STRUCTURAL STEEL COLUMNS WITH THE |
| BASE PLATE TYPES ON THE COLUMN SCHEDULE |
| |
| 14)ADD NOTE TO NEW SLABS THAT TERMITE TREATMENT IS |
| REQUIRED ON ALL EXTERIOR CONCRETE WITHIN 1 FOOT OF |
| PRIMARY STRUCTURE PER 1816.1.6 OR R320.1.6 FBC |
| |
| 15)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER |
| R313.1.1 FBC RES. |
| |
| 16)PROVIDE NOTE FOR BALCONY GUARDRAIL OR SHOW |
| DIMENSIONS THAT MEET THE REQUIREMENTS OF R312.2 FBC |
| RES. |
| |
| BLDG PLAN REVIEW |
| ADRIAN MORSE |
| 561-805-6716 |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |