2007-06-13 08:19:52DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. VALUE IS TO LOW FOR THIS PROJECT, PLEASE PROVIDE
 COPY OF THE CONTRACT TO VERIFY THE VALUE.
 PER FBC-2004, CHAPTER 1, SECTION
 108.3, BUILDING PERMIT VALUATION: IF IN
 THE OPINION OF THE BUILDING OFFICIAL,
 THE CLAIMED VALUATION OF THE BUILDING,
 ALTERATION, STRUCTURE, ELECTRICAL, GAS
 MECHANICAL OR PLUMBING SYSTEMS APPEARS
 TO BE UNDERESTIMATED ON THE APPLICATION,
 THE PERMIT SHALL BE DENIED. FOR
 PERMITTING PURPOSES, VALUATION OF
 BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR
 FINISH, NORMAL SITE WORK (EXCAVATION AND
 BACKFILL FOR BUILDINGS), ARCHITECTURAL
 AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND
 VALUE. VALUATION REFERENCES MAY INCLUDE
 THE LATEST PUBLISHED DATA OF NATIONAL
 CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT,
 MEANS ECT.) WITH
 REGIONAL ADJUSTMENTS FOR LOCATION AS
 PUBLISHED BY INTERNATIONAL CODE
 CONGRESS.
  
 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.1.3
 PLUMBING (9): PLEASE PROVIDE A SANITARY ISOMETRIC
 DRAWING OF GREASE INTERCEPTOR PIPING WITH PIPE SIZES,
 CLEANOUT LOCATIONS, AND GREASE INTERCEPTOR SIZES AND
 LOCATION.
 NOTE: GREASE INTERCEPTOR LOCATION NEEDS APPROVAL FROM
 ENVIRONMENTAL COMPLIANCE DIVISION OF THE UTILITY DEPT.
 PLEASE REFERENCE COMMENT NUMBER THREE (3) FOR
 ENVIRONMENTAL COMPLIANCE INFORMATION.
  
 3. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.1.3
 PLUMBING (12) ENVIRONMENTAL REQUIREMENTS: THE GREASE
 INTERCEPTORS SHALL BE SIZED AND LOCATED BY
 ENVIRONMENTAL COMPLIANCE DIVISION OF THE UTILITY DEPT.
 PLEASE CONTACT RODNEY COMPO, (561) 822-2272 OR CALVIN
 WILLIAMS, (561) 822-2284. THEIR FAX NUMBER IS (561)
 822-2287 AND THEIR E-MAIL ADDRESSES ARE [email protected]
 AND [email protected]. MUNICIPAL CODE ARTICLE III
 SECTION 90-124.
 NOTE: WRITTEN CONFORMATION FROM ENVIRONMENTAL
 COMPLIANCE IS REQUIRED BEFORE PERMIT CAN BE ISSUED.
  
 4. PLEASE INDICATE HOW THE RATE OF FLOW IS TO BE
 CONTROLLED PER FBC-2004 PLUMBING, SECTION 1003.3.4.2:
 GREASE TRAPS SHALL BE EQUIPPED WITH DEVICES TO CONTROL
 THE RATE OF WATER FLOW SO THAT THE WATER FLOW DOES NOT
 EXCEED THE RATED FLOW. THE FLOW-CONTROL DEVICE SHALL BE
 VENTED AND TERMINATE NOT LESS THAN 6 INCHES (152MM)
 ABOVE THE FLOOD RIM LEVEL OR BE INSTALLED IN ACCORDANCE
 WITH THE MANUFACTURER'S INSTRUCTIONS.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721