3 |
|
Notes |
Date |
Text |
2007-08-29 13:03:22 | ****************PROVISO**************** | | A} PER FBC-2004 SECTION 424.2.6.6.3 ENTRAPMENT | | ADVOIDANCE. ALL POOLS AND SPAS SHALL HAVE A BACKUP | | SYSTEM WHICH SHALL PROVIDE VACUUM PROTECTION SHOULD | | GRATE COVERS BECOME MISSING OR INOPERATIVE WITH RESPECT | | TO THEIR APPROVED USE. VACUUM PROTECTION DEVICES SHALL | | CONSIST OF ONE OF THE FOLLOWING: | | | | 1. APPROVED SAFETY VACUUM RELEASE SYSTEM (SVRS). | | | | 2. APPROVED VENT PIPING. | | | | 3. OTHER DEVICES OR MEANS. | | | | NOTE: THE BADU-JET SYSTEM SHALL BE PROTECTED BY ONE OF | | THE ABOVE. | | | | B} SHEET 1, PLUMBING ITEMS INDICATE AN AUTO FILL: THE | | AUTO FILL PIPE SHALL BE INSTALLED BY A LICENSED | | PLUMBING CONTRACTOR WHERE IT CONNECTS TO THE POTABLE | | WATER SYSTEM AND BE INSTALLED PER FBC-2004 PLUMBING | | SECTION 608 PROTECTION OF POTABLE WATER SUPPLY. | | | | REVIEW BY MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL= [email protected] |
|