2007-05-31 15:30:34****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 1.)SHUTTER MOUNTING TYPE "A" IS FOR POURED CONCRETE
 SUBSTRATE, SEE PRODUCT APPROVAL SHEET 14.PLEASE
 ADDRESS.
  
 2.)DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS FS471.025.WIND LOAD CALCULATIONS ARE NOT
 REQUIRED ON BUILDINGS LESS THAN 60' HIGH.
  
  