Plan Review Notes For Permit 07050617 |
Permit Number |
07050617 |
|
Review Stop |
P |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2007-06-07 10:32:39 | DENIED; | | 1. PLUMBING RISER DIAGRAM;BACK TO BACK TOILETS CAN | | NOT BE INSTALLED AS DRAWN. SEE SECTION 706.3. | | 2. BREAK SINK SHALL MEET THE FBC-2004 ACCESSIBLITY | | CODE. CHANGE THE KITCHEN ELEVATION TO SHOW THE | | FOLLOWING INFORMATION; | | 11-4.24.2 HEIGHT OF SINK RIMNO HIGHER THAN 34" | | AFF. | | 11-4.24.3 KNEE CLEARANCE, 27" HIGH, 30" WIDE | | AND 19" DEEP UNDER SINK. ( NO CABINET DOORS) | | 11-4.24.4 SINK SHALL BE A MAX. OF 6 1/2 " DEEP. | | ( SPEC. SINK ON PLANS) | | 11-4.24.5 SHOW CLEAR FLOO SPACE ON FLOOR PLAN. | | 11-4.24.6 INSULATE PLUMBING PIPES AS REQUIRED. | | 11-4.24.7 LEVER OPERATED FAUSET IS REQUIRED. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|