2007-07-27 15:53:35****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)IMPACT PROTECTION IS NOT REQUIRED FOR THIS JOB,
 FBC R301.2.1.2.IF YOU ARE USING REMOVABLE SHUTTERS
 FOR THE WINDOW, PROVIDE HURRICANE SHUTTER PRODUCT
 APPROVAL AND COMPLETE THE ATTACHED INSTALLATION
 SCHEDULE OR PROVIDE THE INFORMATION IN ANOTHER FORMAT.
  
 2.)FOR THE FLAT DECK ROOF, INDICATE WHICH APPROVED
 ASSEMBLY YOU ARE USING.SPECIFY ENHANCED FASTENING FOR
 ZONES 2 AND 3.
  
 NEW COMMENT:
  
 3.)SHOW HOW THE PARAPET WALL WILLR RESIST WIND LOADS
 OF FBC R CHAPTER 3.HOW WILL THE BOLTS KEEP THE WALL
 FROM BEING PUSHED OVER?NO OTHER STRAPPING,
 REINFORCEMENT, OR BRACING IS SHOWN.PROVIDE
 CALCULATIONS.
  
 4.)SPECIFY TYPE OF FASTENER, NOT "A.B."
  
 A SET HAS BEEN RETAINED.
  