2007-05-11 10:57:39DENIED BY BUILDING
  
 1) THE WRONG FLORIDA PRODUCT APPROVAL COVERSHEET WAS
 SUBMITTED. THE CORRECT ONE FOR NOA 03-0501.02 IS FL
 617-R1.
  
 2) SPECIFY WHICH ONE OF THE FASTENING OPTIONS ON PAGE
 28 OF THE NOA WILL BE USED. CIRCLE THE APPROPRIATE ONE
 ON THE NOA.
  
 3) THE LETTER FOR ENHANCED FASTENING THAT WAS SUBMITTED
 IS NOT ACCEPTABLE. THE NUMBER OF ROWS OF NAILS IS NOT
 SPECIFIED. FOR EXAMPLE : FASTENERS AT 4" OC AT THE LAP
 ANDAT 4" OC IN TWO ROWS IN THE FIELD. THE LETTER
 INCORRECTLY SPECIFIES GENERAL LIMITATION #9,WHICH
 DOES NOT ALLOW DESIGN PRESSURES TO BE INCREASED BY
 ENHANCED FASTENING. REVISE TO REFERENCE LIMITATION
 NUMBER 7.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW