2007-05-04 13:48:17****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
 ROOFING PERMIT; ONLY CHECKED ITEMS APPLY
  
 ____1.)A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13.
  
 ____2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING
 INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY;
 MEAN ROOF HEIGHT, ROOF PITCH, ROOF DECK TYPE, AREA OF
 EACH ROOF TYPE
  
 _XX_3.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED IN ADDITION TO THE EVALUATION REPORT
 SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG.THE FL
 PRODUCT APPROVAL PRINTED IS FOR THE LIBERTY SYSTEM.
 THERE IS A DIFFERENT FL PRODUCT APPROVAL FOR THE GAF
 MODIFIED.
  
 _XX_4.)FOR THE FLAT DECK, SELECT THE APPROVED
 ASSEMBLY YOU ARE USING.ALSO INDICATE WHICH FASTENER
 YOU ARE USING IF THE OPTIONS HAVE DIFFERENT PRESSURE
 LIMITATIONS.
  
 _XX_5.)REGARDING THE ENHANCED FASTENING NAILING
 PATTERN,I CANNOT DETERMINE WHETHER OR NOT IT IS
 COMPLIANT DUE TO INSUFFICIENT INFORMATION. NOTE WHICH
 FASTENING OPTION YOU ARE USING (SEE ITEM 4).STATE HOW
 MANY FIELD ROWS ARE TO BE INSTALLED.ALSO PLEASE
 PROVIDE CALCULATIONS FOR THE ENHANCED FASTENING PER
 RAS117.THIS IS BEING REQUESTED BECAUSE YOU HAVE A
 DIFFERENT FASTENING SPACING FOR THE LAP AND FIELD, BUT
 RAS117 REQUIRES THAT BOTH LAP AND FIELD FASTENING BE
 THE SAME.THE ALTERNATE FASTENING PATTERN MAY BE
 ACCEPTABLE IF IT EXCEEDS THE REQUIREMENTS OF RAS117,
 BUT I CANNOT DETERMINE COMPLIANCE WITH THE INFORMATION
 PROVIDED.IF YOU USE THE SYSTEM WITH THE -45PSF DP,
 6INCH, 3 ROWS TOTAL (2 FIELD ROWS, ONE ROW AT THE LAP)
 REQUIRED AT 6" EACH, SO THE ENHANCED FASTENING
 SPECIFIED WOULD NOT BE IN ACCORDANCE WITH RAS117.
  