Plan Review Notes For Permit 07050168 |
Permit Number |
07050168 |
|
Review Stop |
B |
Sequence Number |
3 |
|
Notes |
Date |
Text |
2007-05-23 07:44:33 | DENIED BY BUILDING | | | | 1) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) IN ADDITION TO THE FL COVERSHEETS, SUBMIT TWO COPIES | | OF NOA 05-1115.08 FOR THE GAF TIMBERLINE SHINGLES. | | | | 3) THE PRODUCT APPROVAL SUBMITTED IS FOR TAMKO MODIFIED | | ROOF SYSTEM OVER RECOVER DECKS. THE DESCRIPTION OF WORK | | ON THE PERMIT APPLICATION IS FOR TEAR OFF. PLEASE | | CLARIFY. | | NOTE: IF THIS IS A RECOVER (ROOF-OVER), A | | PRE-INSPECTION BY THIS DEPARTMENT IS REQUIRED TO | | DETERMINE THE EXISTING ROOF CONDITION. | | | | 4) SPECIFY ON THE PRODUCT APPROVAL WHICH ONE OF THE | | SYSTEMS WILL BE USED, WHICH ONE OF THE FASTENING | | OPTIONS AND UPLIFT PRESSURES WILL BE USED AND THE DECK | | TYPE (WOOD,CONCRETE, ETC.) | | | | 5) IF THE UPLIFT FOR THE SYSTEM REQUIRES ENHANCED | | FASTENING AND IT IS ALLOWED BY GENERAL LIMITATION | | NUMBER 7, SUBMIT RAS 117 CALCULATIONS. IF LIMITATION | | NUMBER 7 OF THEPRODUCT APPROVAL REQUIRES THE RAS 117 | | CALCULATIONS TO BE DONE BY AN ENGINEER, ARCHITECT OR | | REGISTERED ROOF CONSULTAN, THEY ARE REQUIRED TO BE | | SIGNED AND SEALED. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | | | | | |
|