Date |
Text |
2007-05-30 16:12:43 | PLANNING AND ZONING DEPARTMENT |
| |
| ***FAILED*** |
| |
| 1. PROVIDE TWO (2) SIGNED AND SEALED SURVEYS.SURVEY |
| SHALL BE LESS THAN A YEAR OLD. |
| |
| 2. PROVIDE A LETTER FROM THE ENGINEERING SERVICES |
| DEPARTMENT APPROVING THE PROPOSED ON-STREET PARKING |
| SPACES.THE LETTER SHALL ALSO STATE THE TOTAL NUMBER |
| OF AVAILABLE PARKING SPACES ALONG KANUGA DRIVE. |
| A. PLEASE NOTE THAT ALL ON-STREET PARKING SPACES SHALL |
| BE DELINEATED PRIOR TO BUILDING PERMIT APPROVAL. |
| B. PROVIDE WIDTH AND DEPTH DIMENSIONS OF ALL APPROVED |
| ON-STREET PARKING SPACES ON THE SITE PLAN. |
| C. PROVIDE PARKING STALL DETAILS OF ALL APPROVED |
| ON-STREET PARKING SPACES. |
| D. PLEASE NOTE THAT FOUR (4) PARKING SPACES, ONE OF |
| WHICH SHALL BE A HANDICAP PARKING SPACE, SHALL BE |
| MAINTAINED FOR THIS SITE. |
| |
| 3. HANDICAP SYMBOL SHALL BE TWO (2) FEET FROM THE OPEN |
| END OF THE PARKING SPACE. |
| |
| 4. PROVIDE DIMENSIONS OF THE AISLE WIDTH.PLEASE NOTE |
| THAT PER SECTION 94-485(J) OF THE ZONING AND LAND |
| DEVELOPMENT REGULATIONS, TWO-WAY DIRECTION MOVEMENT |
| REQUIRES A MINIMUM OF 24 FEET WIDE REGARDLESS OF |
| PARKING ANGLE AND DIMENSIONS. |
| |
| 5. PURSUANT TO SECTION 94-441(C) OF THE ZONING AND LAND |
| DEVELOPMENT REGULATIONS, RENOVATIONS, REPAIRS, |
| ALTERATIONS OR REDEVELOPMENTS WHICH EXCEED 50 PERCENT |
| OF THE VALUE OF THE STRUCTURE SHALL COMPLY WITH THE |
| PROVISIONS OF ARTICLE XIV, LANDSCAPING, LAND CLEARING, |
| AND TREE PROTECTION, OF THE ZONING AND LAND DEVELOPMENT |
| REGULATIONS. |
| A. A LANDSCAPE PLAN, PREPARED, SIGNED AND SEALED BY A |
| REGISTERED LANDSCAPE ARCHITECT, AND MEETING THE |
| PROVISIONS OF ARTICLE XIV, LANDSCAPING, LAND CLEARING, |
| AND TREE PROTECTION, OF THE ZONING AND LAND DEVELOPMENT |
| REGULATIONS SHALL BE PROVIDED. |
| B. THE LANDSCAPE REGULATIONS MAY BE VIEWED ONLINE AT |
| WWW.MUNICODE.COM. |
| C. PLEASE PROVIDE THE APPRAISED VALUE OF THE STRUCTURE. |
| THE TOTAL VALUE OF THE PERMITS FOR THE RENOVATION OF |
| THE BUILDING WILL BE CALCULATED TO DETERMINE THE 50 |
| PERCENT THRESHOLD . |
| |
| 6. PROVIDE LANDSCAPE CALCULATIONS OF WHAT IS EXISTING |
| VS. WHAT IS PROPOSED. |
| |
| 7. A TREE REMOVAL LICENSE APPLICATION SHALL BE |
| SUBMITTED TO THE PLANNING AND ZONING DEPARTMENT FOR ALL |
| TREES (7 PALMS) THAT WILL BE REMOVED AND/OR RELOCATED. |
| |
| |
| 8. PROVIDE REAR SETBACK DIMENSION. |
| |
| 9. THE PROPOSED FENCE/WALL IS LOCATED WITHIN THE |
| VISIBILITY TRIANGLE.PLEASE NOTE THAT PER SECTION |
| 94-305(E) OF THE ZONING AND LAND DEVELOPMENT |
| REGULATIONS, AT ANY ROAD INTERSECTIONS, VISIBILITY |
| SHALL NOT BE OBSCURED BY ANY ITEM BETWEEN 18 INCHES OR |
| 8 FEET IN HEIGHT WITHIN A TRIANGLE BEGINNING AT THE |
| POINT WHERE PROPERTY LINES MEET AT THE CORNER, THEN 20 |
| FEET ALONG THE FRONT PROPERTY LINE, THENCE DIAGONALLY |
| TO A POINT ALONG THE SIDE PROPERTY LINE 20 FEET FROM |
| THE POINT OF BEGINNING, AND THEN TO THE POINT OF |
| BEGINNING.SHEET S.2 INCORRECTLY SHOWS THE VISIBILITY |
| TRIANGLE BEING AT THE POINT WHERE THE CURBS MEET. |
| |
| 10. THE PROPOSED GATE ALONG THE WEST PROPERTY LINE |
| SHALL BE NO LESS THAN 24 FEET WIDE. |
| |
| 11. PLEASE NOTE THAT A RIGHT-OF-WAY PERMIT SHALL BE |
| SUBMITTED FOR THE REPLACEMENT OF THE EXISTING |
| SIDEWALK. |
| |
| 12. PLEASE NOTE THAT THE LOCATION MAP HIGHLIGHTS TWO |
| (2) DIFFERENT PROPERTIES/LOCATIONS. |
| |
| COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC |
| SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
2007-05-17 09:03:35 | NEEDS |