Date |
Text |
2008-06-19 14:17:22 | ****************PROVISO**************** | | THE FOLLOWING IS REQUIRED FOR THE CLEANOUTS PER FBC - | | PLUMBING SECTIONS. | | (A) 708.3.4 BASE OF STACK. A CLEANOUT | | SHALL BE PROVIDED AT THE BASE OF EACH | | WASTE OR SOIL STACK | | (B) 708.3.5 BUILDING DRAIN AND BUILDING | | SEWER JUNCTION. THERE SHALL BE A TWO-WAY | | CLEANOUT NEAR THE JUNCTION OF THE | | BUILDING DRAIN AND THE BUILDING SEWER. | | | | REVIEW BY: MIKE PERSON | | PLUMBING PLANS EXAMINER | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL: [email protected] |
|