Plan Review Notes For Permit 07040727
Permit Number 07040727
Review Stop B
Sequence Number 2
Notes
Date Text
2008-03-08 11:26:00 
  
  
 DENIED
  
 THE FOLLOWING COMMENTS WERE NOT ADDRESSED ON THE 1ST
 REVIEW
  
  
 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES ******FEES ADDED
 DUE TO INCREASED SQUARE FOOTAGE******
  
 3)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*. FEES ARE DUE FOR THE STATE RADON AND
 THE INCREASED PERMIT VALUE IN THE AMOUNT OF $718.85
 THIS MUST BE PAID BEFORE FURTHER PLAN REVIEW IS
 PERFORMED.********THE INCREASE IN VALUE IS DUE TO
 ADDED SQUARE FOOTAGE, VALUE BASED ON BUILDING VALUATION
 DATA FROM FEB 2007 WHEN FIRST PERMITTED*********
  
 5)SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR
 BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD. ******THIS MAY BY
 DELIVERED TO SITE INSPECTOR PRIOR TO ROOF FRAMING
 INSPECTION******
  
 10)THE FOLLOWING CORRECTIONS ARE REQUIRED FOR THE
 PRODUCT APPROVALS:
 A)PRODUCT APPROVALS ARE REQUIRED FOR CASTCRETE
 LINTELS OR THE FLORIDA STATEWIDE APPROVAL NUMBER ADDED
 TO THE LINTEL SCHEDULE
 B)PRODUCT APPROVALS ARE REQUIRED FOR SIMPSON/USP
 CONNECTOR OR THE STATEWIDE APPROVAL NUMBERS MAY BE
 ADDED TO THE CONNECTOR SCHEDULE ******* IN LUE OF
 PRODUCT APPROVALS STRAPS/CONNECTORS MAY BE LISTED IN A
 SCHEDULE ON THE DRAWINGS COMPLETE WITH THE STATEWIDE
 PRODUCT APPROVAL NUMBERS OR SUBMIT SIMPSON TIE?S
 COMPLETE FLORIDA INDEX WITH CONNECTORS TO BE USED
 HIGHLIGHTED*********
  
 2ND REVIEW COMMENTS
  
 1)PLANS AND SPECIFICATIONS DESIGN PARAMETERS SHALL
 COMPLY WITH THE 2004 FLORIDA BLDG CODE WITH 2006
 AMENDMENTS PER 106.1.1 FBC*
  
 2)PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN
 COMPLIANCE WITH THE REQUIREMENTS OF R403.1 FBC RES.
  
 3)PROVIDE SMOKE ALARMS TO EXISTING BUILDING PER
 R313.1.1 FBC RES.
  
 4)PROVIDE MIN ROOF SHEATHING ATTACHMENT PER
 R803.2.3.1 FBC RES. ***** REQUIRES 8D RING SHANK AND A
 4" O/C PATTERN IN ZONE 3 OF ROOF IN AREAS WHERE DESIGN
 WIND SPEEDS ARE 130 MPH OR GREATER
  
 5)SUBMIT A COPY OF THE RECORDED NOTICE OF
 COMMENCEMENT TO THE CONSTRUCTION SERVICES DEPARTMENT.
  
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  