2007-06-04 16:35:53BUILDING PLAN REVIEW
 PERMIT: 07040698
 ADD: 6118 WILDCAT RUN
 CONT: WILLIAM BELL CONSTRUCTION
 TEL: (561)741-8655
  
  
 FL BLD CODE= 2004 FLORIDA RESIDENTIAL CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 2NDREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 SUBMITTED ARE MANUFACTURERERS SPECS FOR MAJESTIC BR/BC
 WOODBURNING FIREPLACES
  
 HIGHLIGHTED ON SHEET 20 UNDER CAUTION:IT STATES IF
 YOU USE AN UNAPPROVED COMPONENT TO MAKE ANY
 MODIFICATIONS, YOU MAY CREATE A POSSIBLE FIRE HAZARD
 AND WILL VOID THE CFM CORPORATION WARRANTY.
 RESIDENTIAL CODE 1002.1 FACTORY-BUILT CHIMNEYS SHALL BE
 LISTED AND LABELED AND SHALL BE
 INSTALLED AND TERMINATED IN ACCORDANCE WITH THE
 MANUFACTURER'S INSTALLATION INSTRUCTIONS.
  
 R1002.2 DECORATIVE SHROUD. DECORATIVE SHROUDS SHALL NOT
 BE INSTALLED AT THE TERMINATION OF A FACTORY-BUILT
 CHIMNEYS EXCEPT WHERE SHROUDS ARE LISTED AND LABELED
 FOR USE WITH THE SPECIFICFACTORY-BUILT CHIMNEY
 SYSTEMAND INSTALLED IN ACCORDANCE WITH THE MANUFACTER'S
 INSTALLATIONINSTRUCTIONS.
  
 RESIDENTIAL CODE 1002.1 FACTORY-BUILT CHIMNEYS SHALL BE
 LISTED AND LABELED AND SHALL BE INSTALLED AND
 TERMINATED IN ACCORDANCE WITH THE MANUFACTURER'S
 INSTALLATION INSTRUCTIONS.
 PLEASE PROVIDE THE MANUFACTURER'S INSTALLATION
 INSTRUCTIONS IT APPEARS IN THIS DRAWING THESPARK
 ARESTOR IS MISSING.
  
 DESIGN#1 FROM ARCHITECT STEPHENYECKES; WRITTEN
 NOTIRIZED PERMISSION WILL NEED TO BE SOUGHT FROM THE
 MANUFACTURERER FOR THE PROPOSED DECORATIVE WEATHER
 HEAD. IN SPEAKING WITH THE DESIGN PROFESSIONAL IT WAS
 STATED WRITTEN APPROVAL MUST BE OBTAINED, AND NO
 COMBUSTIBLE MATERIAL WOULD BE ALLOWED ABOVE THE PAN
 FLASHING AND STORM COLLAR. IN THE PRESENT DESIN PLANS
 STILL INDICATE THE USE OF FOAM TRIM AND THE DECKING FOR
 THE WALLS AND ROOF SHEATHING AREN'T IDENTIFIED. PLANS
 ALSO NOW INDICATE THE FRAMING TO BE METAL STUDS BUT NO
 CONSIDERATION HAS BEEN GIVEN TO BRACING NOR THE BOTTOM
 ANCHOR HAS BEEN IDENTIFIED.
  
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]