Date |
Text |
2007-07-19 14:39:53 | BUILDING PLAN REVIEW |
| PERMIT: 07040689 |
| ADD:2235 OKEECHOBEE BLVD |
| CONT: BENCHMARK III CORP |
| TEL: (561)744-8686 |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2006 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| REVIEW 2ND |
| ACTION: DENIED |
| |
| 1)OK |
| |
| 2)11-4.26.1ALL HANDRAILS, GRAB BARS, AND TUB AND |
| SHOWER SEATS REQUIRED TO BE ACCESSIBLE BY SECTION |
| 11-4.1 , 11-4.8 , 11-4.9 , 11-4.16 , 11-4.17 , 11-4.20 |
| OR 11-4.21 SHALL COMPLY WITH SECTION 11-4.26 . INDICATE |
| THE TYPE OF BACKING WHICH WILL MEET THE 250LB BENDING |
| MOMENT REQUIREMENT STATED IN SECTION(11-4.26.3). |
| |
| 3) THE CERTIFICATE OF AUTHORIZATION NUMBER OF ARCHITECT |
| AND ASSOCIATES, P.A.SHALL BE INDICATED IN THE TITLE |
| BLOCK ON EACH PAGE. |
| 61G1-16.004 TITLE BLOCK. |
| A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL OR |
| INTERIOR DESIGN DRAWINGS AND SPECIFICATION |
| IDENTIFICATION SHEETS. THE TITLE BLOCK MUST, AT A |
| MINIMUM, CONTAIN THE FOLLOWING INFORMATION: |
| (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER. |
| (2) FIRM LICENSE NUMBER. |
| (3) NAME OR IDENTIFICATION OF PROJECT. |
| (4) DATE PREPARED. |
| (5) A SPACE FOR THE SIGNATURE AND DATED SEAL. |
| (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING |
| THE DOCUMENT. |
| |
| 4 ) FL S S 713.13 |
| NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF |
| THE COURT. |
| NOTE: 713.13(2) |
| IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS |
| NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE |
| RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: |
| 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT |
| THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| |
| 5)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS |
| LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST |
| EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC |
| (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES |
| PER 108.3 FBC* |
| |
| NEW***** |
| 6)FBC 1210.2 WALLS WITHIN 2 FEET OF UNIRALS AND |
| WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT |
| SURFACE, TO A HEIGHT OF 4 FEET ABOVE THE FLOOR, AND |
| EXCEPT FOR STRUCTUREAL ELEMENTS, THE MATERIALS USED IN |
| SUCH WALLS SHALL BE OF A TYPE THAT IS NOT ADVERSELY |
| AFFECTED BY MOISTURE. INDICATE CLEARLY ON THE PLANS THE |
| FINISH FOR THE BATHROOM WALLS MEETING THE REQUIREMENTS |
| OF THIS SECTION. |
| |
| MYRON JACOBS |
| BUILDING PLAN REVIEWER |
| 805-6726 |
| |