2007-05-03 16:59:49 | BUILDING REVIEW CHECKLIST: |
| 1- PROVIDERECORDED NOTICE OF COMMENCEMENT AS REQUIRED |
| BY SEC. 713.13 FLORIDA STATUTE. |
| |
| 2- PAY IMPACT FEES TO PALM BEACH COUNTY.AFTER PLANS |
| ARE REVISED, BRING THEM TO PALM BEACH COUNTY, |
| (561)233-5115,BRING BACK STAMPED PLANS AND COPY OF |
| PAID RECEIPT. |
| |
| 3- SOIL TEST REPORT: |
| A) PROVIDE TWO COPIES WITH ORIGINAL SEAL, SIGNATURE |
| AND DATE AS REQUIRED BY SEC.61G15-23.002 OF FLORIDA |
| ADMINISTRATIVE CODE. |
| |
| B) INDICATE IN ALL SHEETS ENGINEERING FIRM |
| CERTIFICATE OFAUTHORIZATION NUMBER AS REQUIRED BY |
| SEC. 61G15-23.002 FLORIDA ADMINISTRATIVE CODE. |
| |
| 4- PROVIDE DRAINAGE PLAN AS REQUIRED BY SEC. R401.3 OF |
| 2004 FLORIDA RESIDENTIAL CODE. |
| ***NOTE: WATER SHALL BE DIVERTED AWAY FROMNEIGHBOR'S |
| PROPERTY. |
| |
| 5- PROVIDE COMPLETE DETAILS AND SPECS SHOWING HOW TO |
| KEEP CONTINUITY OF TIE BEAMAT WINDOW OPENING LOCATED |
| IN THE STAIRWAY. SEE LEFT SIDE ELEVATION ON SHEET A-2. |
| SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. |
| |
| 6- AFTER PLANS ARE REVISED, BRING THEM BACK TO FIFTH |
| FLOOR FOR HISTORICAL APPROVAL STAMP PRIOR TO SUBMITTAL |
| TO THIS OFFICE. |
| |
| 7- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE |
| 9B-72 FOR: |
| A) CUSTOM ENTRY DOOR AS SHOWN ON PLANS. SEE PLANS |
| FOR HEIGHT AND SHAPE. |
| |
| B) FRENCH DOORS. INFORMATIONSUBMITTED IS MISSING |
| THE DRAWINGS. |
| |
| C) PRECAST LINTELS. |
| |
| D) EXTERIOR SIDE GARAGE SWING DOOR. |
| |
| E) GARAGE DOOR.INFORMATIONSUBMITTED IS MISSING |
| THE DRAWINGS. |
| |
| F) FLAT ROOF: |
| * NEED TO SPECIFY SPECIFIC APPROVED ASSEMBLY TO BE |
| INSTALLED.CIRCLED ASSEMBLY ON PAGE 18 OF 19 IF FOR |
| TILE UNDERLAYMENT ONLY. NEED SPECIFIC ASSEMBLY FOR FLAT |
| ROOF INSTALLATION. |
| ** IF MORE THAN ONE FASTENING OPTION IS SHOWN ON |
| SELECTED ASSEMBLY, THEN SPECIFY FASTENING OPTION. |
| *** PROVIDE RAS 117 CALCULATIONS FOR ENHANCED |
| FASTENING AT PERIMETER AND CORNER AREAS AS REQUIRED BY |
| GENERAL LIMITATION #7. SEE GENERAL LIMITATION #7 ON |
| SHEET 19 OF 19 OF NOA 04-0506.03 SUBMITTED. |
| **** NOTE: KEEP IN MIND THAT NOA 04-0506.03 EXPIRES ON |
| MAY 23RD, 2007. |
| |
| 8- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| (NOT SIGNING AND SEALING)ALL PRODUCT APPROVALS AS |
| REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004 |
| |
| 9- ENERGY CALCULATIONS: |
| A) NEED TO USE REVISED FORM 600A-2004 R. |
| |
| B) PROVIDE COMPLETE AND CORRECT INFORMATION ON TOP |
| OF FORM. |
| |
| C) IF THIS IS NOT WORST CASE SCENARIO, THEN |
| CALCULATIONS MUST BE DONE TO THE SPECIFIC ORIENTATION |
| OF THE HOUSE. SEE SURVEY FOR CORRECT ORIENTATION AND |
| REVISE AS REQUIRED. |
| |
| D) REVISE/CLARIFY WALL TYPES.WHICH ONE ARE THE |
| CONCRETEINTERIOR WALLS AND WHICH ARE THE CONCRETE |
| EXTERIOR WALLS. SEE PLANS. |
| |
| E) PROFESSIONAL WHO SIGNED AND SEALEDTHE ENERGY |
| CALCULATIONS NEED TO PROVIDE ALL HIS/HERINFORMATION |
| AS REQUIRED BY CHAPTER 481 AND CHAPTER 471 OF FLORIDA |
| STATUTES. |
| |
| F) OVERHANG LENGTH AND HEIGHT IS INCORRECT. REVISE |
| AS REQUIRED. IT CAN'T BE ZERO. SEE PLANS AND REVISE AS |
| REQUIRED. |
| |
| 10- SHEET T-1: |
| A)BUCK DETAILS: SPECIFY HOW MUCH EMBEDMENT IS |
| REQUIRED FOR SPECIFIED TAPCONS.SEC. 106.1.2 CITY |
| AMENDMENTS TO FBC 2004. |
| |
| B) REVISE WINDOW BUCK DETAIL. SEE SEC. R613.6.2 OF |
| 2004 FLORIDARESIDENTIAL CODE FOR PROPER WAY OF |
| INSTALLINGSTRUCTURAL BUCKS. |
| |
| C) REVISE PROJECT DESIGN INFORMATION. THERE IS NOT |
| FBCSEC. 1606.1.7 . SEE FBC 2004 ALONG WITH REVISIONS. |
| ON THE OTHER HAND,CODE TO REFERENCE IS THE FLORIDA |
| RESIDENTIAL CODE OF 2004.SEE SEC. R301 AND TABLE |
| R301.5 OF FLORIDA RESIDENTIAL CODE 2004 AND SPECIFY ALL |
| LOADS, INCLUDING LIVE AND DEAD LOADS. |
| ALSO, WHAT'S WIND SPEED (V)?. |
| |
| 11- BEDROOM WINDOW SINGLE HUNG 24 DOESN'TCOMPLY WITH |
| EGRESS REQUIREMENTS OF SEC. R310.1 OF 2004 FLORIDA |
| RESIDENTIAL CODE. REVISE AS REQUIRED. |
| |
| 12- STAIRCASE: |
| A) PROVIDE COMPLETE INFORMATION AS REQUIRED BY SEC |
| R311.5.3 AND SEC. R311.6 OF 2004 FLORIDA RESIDENTIAL |
| CODE. |
| |
| B) SPECIFY FIREBLOCKING AS REQUIRED BY SEC. R602.1.2 |
| OF 2004 FLORIDA RESIDENTIAL CODE. |
| |
| 13- PROVIDE COMPLETE INFORMATION FOR BALCONY GUARDRAIL |
| AS REQUIRED BY SEC. R312 OF 2004 FLORIDA RESIDENTIAL |
| CODE. |
| |
| 14- PROVIDE SPECIFICATIONS FOR GARAGE INTERIOR DOOR AND |
| CEILING CONSTRUCTION AS REQUIRED BY SEC. R309 OF 2004 |
| FLORIDA RESIDENTIAL CODE. |
| |
| 15- PROVIDE FIREPLACE SPECS AND LISTING AS REQUIRED BY |
| SEC. R1002 OF 2004 FLORIDA RESIDENTIAL CODE. |
| |
| 16- PROVIDE DIMENSIONS FOR BALCONY. |
| |
| 17- SHEET A-2: |
| A) CLARIFY CONSTRUCTION AT BOTTOM OF CHIMNEY.LEFT |
| SIDE ELEVATION SHOWS CANTILEVERED FIREPLACE.REVISE AS |
| REQUIRED. |
| |
| B) PROVIDE COMPLETE INFORMATION ON SECTION AT GARAGE |
| ROOF. NEED TO SPECIFY ALL FASTENERS. IS THIS A |
| CANTILEVERED ROOF? . SECTION 106.1.2 CITY AMENDMENTS TO |
| FBC 2004. |
| |
| 18- SPECIFY HOW MANY NAILS ARE REQUIRED FOR THE ROOF |
| TILE.ALSO, CLARIFY IF SUING POLY FOAM OR NAILS OR |
| BOTH. THERE WAS A PRODUCT APPROVAL SUBMITTED FOR |
| POLYFOAM. CLARIFY AS REQUIRED. |
| |
| 19- SHEET A-3: |
| A) PROVIDE COMPLETE SPECS FOR BALCONY CONSTRUCTION. |
| NEED HANDRAIL INFORMATION AND BALCONY FLOOR COMPLETE |
| SPECIFICATIONS. SEC. 106.1.2 CITY AMENDMENTS TO FBC |
| 2004. |
| |
| B) PROVIDE COMPLETE SPECIFICATIONS FORFRAMED WALL |
| AT ROOF AREA. SEE SECTION 11/A-3.SEC. 106.1.2 CITY |
| AMENDMENTS TO FBC 2004. |
| |
| C) REVISE FURRING SPECS ON WALL SECTIONS TO MATCH. |
| SOME SECTIONS CALLS 16" O.C. SPACING WHILE OTHER |
| SECTIONS CALL FOR 24"O.C. SPACING. |
| |
| 20 PROVIDE COMPLETE SPECIFICATIONS SHOWING COMPLIANCE |
| WITH VENTILATION REQUIREMENTSFOR FLAT AND PITCHED |
| ROOF AS REQUIRED BY SEC. R806 OF 2004 FLORIDA |
| RESIDENTIAL CODE. |
| |
| 21- PROVIDE COMPLETE DETAILS/SECTIONS FOR CONSTRUCTION |
| OF ALL ARCHED OPENINGS. SEC. 106.1.2CITY AMENDMENTS |
| TO FBC 2004. |
| |
| 22- OWES $2568.10 FOR UPDATED VALUATION,RADON FEES |
| AND BALANCE ON PERMIT APPLICATION. |
| |
| 23- CONTRACTOR TO UPDATE INSURANCE WITH PERMIT CLERK. |
| |
| 24- SHEET S-1: |
| A) PROVIDE COMPLETE DETAILS AND SPECS FOR COLUMNS |
| WC1 AND WC2. SPECIFY ALL FASTENERS. SEC. 106.1.2 CITY |
| AMENDMENTS TO FBC 2004. |
| |
| B) SPECIFY SIZE OF SPANSION ANCHOR IN DETAIL 1/S-1. |
| SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. |
| |
| C) TRUSS CONNECTOR SPECIFIEDDOESN'T WORK FOR |
| PROPOSED INSTALLATION.SEE CATALOG FOR PROPER |
| CONNECTOR AND REVISE AS REQUIRED.SEC. 106.1.2 CITY |
| AMENDMENTS TO FBC 2004. |
| ALSO, SPECIFY ON PLANS TRUSS CONNECTOR. NONE WAS |
| KEYED. |
| |
| 25- SHEET S-2: |
| A) REVISE TRUSS ANCHOR SCHEDULE. SEE CURRENT CATALOG |
| FOR PUBLISHED LOADS AND FASTENERS. OTHERWISE, PROVIDE |
| COMPLETE ENGINEERING ANALYSIS FOR NUMBERS AND LOADS |
| THAT DIFFER FROM THOSE TESTED AND PUBLISHED BY THE |
| MANUFACTURER. SEC. 106.1.2 CITY AMENDMENTS TO FBC |
| 2004. |
| |
| B) SPECIFY TRUSS CONNECTORS ON ROOF FRAMING PLAN. |
| NONE WAS KEYED. |
| |
| C) REVISE CONNECTOR SPECIFIED FOR CUPOLA ROOF ON |
| FRONT WALL.ROOF IS RESTING ON MASONRY WALL. NEED TO |
| SPECIFY WOOD TO MASONRY CONNECTOR. SEC. 106.1.2 CITY |
| AMENDMENTS TO FBC 2004. |
| |
| JULIO GOMEZ |
| BUILDING PLANS EXAMINER |
| (561)805-6712 |