Plan Review Notes For Permit 07040408 |
Permit Number |
07040408 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2007-05-01 17:49:43 | | | | | DENIED | | | | 1)SHUTTER PERMIT APPLICATIONS REQUIRE A KEY PLAN, | | SHUTTER SCHEDULE AND THE PRODUCT APPROVALS. DRAWINGS | | CAN BE MARKED WITH THE INFORMATION SPECIFIC TO THE SITE | | (TYPE OF CONSTRUCTION, MOUNTING CONNECTION METHOD, | | ANCHOR TYPE, SHUTTER SPAN (VERTICAL OR HORIZONTAL), | | ETC.) PLEASE SEE THE ATTACHED MEMO AND SCHEDULE. | | BUILDINGS OVER 60 FEET IN HEIGHT ALSO REQUIRE | | ENGINEERED WIND LOADS TO BE PROVIDED. | | | | 2)PLEASE MAKE COPIES OF THE SUPPLIED INSTALLATION | | SCHEDULE AND SUBMIT WITH ALL OF THE INFORMATION THAT | | PERTAINS TO EACH INDIVIDUAL SHUTTER | | | | 3)MAKE CLEAR WHICH OPENINGS ARE ACCORDIONS, DIFFERENT | | INFO ON THE PRESSURE CALC SHEET AND THE KEY PLAN. | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|