Plan Review Notes For Permit 07040308 |
Permit Number |
07040308 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2007-04-17 20:09:39 | PRELIMINARY INSPECTION FAILED: SEE FEBC SECTION 511.3 | | (5). | | | | 511.3RECOVERING VERSUS REPLACEMENT. | | NEW ROOF COVERINGS SHALL NOT BE INSTALLED WITHOUT FIRST | | REMOVING EXISTING ROOF COVERINGS WHERE ANY OF THE | | FOLLOWING CONDITIONS OCCUR: | | 1. WHEN THE OLD ROOFING IS WATER-SOAKED OR DETERIORATED | | TO THE POINT THAT IT IS NOT SUITABLE AS A BASE FOR | | ADDITIONAL ROOFING. | | 2. WHEN BLISTERS EXIST IN ANY ROOFING, UNLESS BLISTERS | | ARE CUT OR SCRAPED OPEN AND NAILED DOWN BEFORE APPLYING | | ADDITIONAL ROOFING. | | 3. WHEN THE EXISTING ROOF SURFACE IS GRAVEL OR THE | | LIKE, THE GRAVEL SHALL BE THOROUGHLY REMOVED OR ALL | | LOOSE GRAVEL REMOVED AND APPROVED BASE MATERIAL | | INSTALLED BEFORE APPLYING ADDITIONAL ROOFING. 4. WHEN | | EXISTING ROOF IS SLATE OR THE LIKE. 5. WHEN SHEATHING | | OR SUPPORTS ARE DETERIORATED TO THE POINT THAT THE ROOF | | STRUCTURAL SYSTEM IS NOT SUBSTANTIAL ENOUGH TO SUPPORT | | RECOVERING. | | 6. WHEN EXISTING ROOF HAS TWO OR MORE APPLICATIONS OF | | ANY TYPE ROOFING MATERIAL. CONFORMANCE WITH THIS ITEM | | SHALL MAKE REPLACEMENT MANDATORY. |
|