2007-04-09 11:58:05 | ****CORRECTIONS**** |
| |
| SAMANTHA HILL, BUILDING PLANS EXAMINER |
| 561-805-6724 [email protected] |
| |
| FBCFLORIDA BUILDING CODE 2004 |
| FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING |
| CODE |
| FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* |
| CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC |
| FLORIDA ADMINISTRATIVE CODE |
| FSFLORIDA STATUTE |
| |
| 1.)TWO ORIGINAL SETS OF ALL PERMIT DOCUMENTS |
| REQUIRED, FBC*106.1.ONLY ONE SET OF ENGINEERING WAS |
| SUBMITTED. |
| |
| 2.)THE ENGINEER SPECIFIES TIN CAP NAILING AND MAKES |
| NO REFERENCE TO THE SPECIFIC NOA OR ASSEMBLY.THE |
| ASSEMBLY SPECIFIES SIMPLEX MEGA CAP NAILS. |
| |
| 3.)THE ENGINEERING SPECIFIES SPACING BUT NOT NUMBER |
| OF ROWS. |
| |
| 4.)THE ENGINEER SPECIFIES 3" SPACING.SEE RAS117 8.1 |
| IN REGARDS TO MINIMUM FASTENER SEPARATION. |
| |
| 5.)PROVIDE CALCULATIONS IN ACCORDANCE WITH RAS117; |
| SEE GENERAL LIMITATION #7 OF THE NOA.ONLY A |
| SPECIFICATION WAS PROVIDED; CALCULATIONS ARE REQUIRED. |
| |
| 5.)SEE ATTACHED POLICY IN REGARDS TO INFORMATION TO |
| BE INCLUDED IN THE PRODUCT APPROVAL.NOT ENOUGH SHEETS |
| WERE PROVIDED.IF YOU ARE UNSURE AS TO WHAT TO SUBMIT |
| (BUT FIRST PLEASE READ THE POLICY AS IT SPECIFICALLY |
| STATES WHAT IS REQUIRED), SUBMIT A COMPLETE PRODUCT |
| APPROVAL WITH THE APPROVED ASSEMBLY CLEARLY MARKED AND |
| I WILL REMOVE THE UNNECESSARY SHEETS. |
| |
| 6.)THE ENGINEERING HAS BEEN RETAINED. |