Plan Review Notes
Plan Review Notes For Permit 07030795
Permit Number 07030795
Review Stop B
Sequence Number 2
Notes
Date Text
2007-04-21 11:53:40****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FACFLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
  
 1.)YOU HAVE REDUCED THE PRESSURE TO -47.2.THIS IS
 "WORST CASE" FOR ZONE 5, EXPOSURE B.THIS JOB IS
 EXPOSURE C; SEE FBC1609.6.2.1(2), FBC R301.2.1.4.
 OPENING 9 REQUIRES A -53.24PSF.SEE FBC TABLE R
 301.2(2) AND FBC R301.2.(3).REVISE PRESSURE AND CHECK
 ANCHOR SPACING FOR ALL OPENINGS.
  