Date |
Text |
2007-04-09 15:57:52 | DENIED |
| REFERENCE: |
| ** FBC-2004 PLUMBING. |
| ** FBC-2004 CHAPTER 1, THE CITY OF |
| WEST PALM BEACH AMENDMENTS. |
| |
| THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR |
| PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: |
| |
| 1. MORE INFORMATION IS REQUIRED. PLEASE INDICATE ON |
| THE RESUBMITTED DRAWINGS WHAT IS REQUIRED IN COMMENT #2 |
| BEING THAT THE NEW PROPOSED PLUMBING LAYOUT IS |
| DIFFERENT FROM THE EXISTING. |
| |
| 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4 |
| RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A |
| PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING |
| ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT |
| LOCATIONS FOR THE RESUBMITTAL WITH THE FOLLOWING |
| INFORMATION. |
| |
| (A) 406.3 WASTE CONNECTIONS.THE TRAP AND |
| FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES |
| WASHER SHALL BE A MINIMUM OF 2 INCHES |
| (51MM) IN DIAMETER. THE AUTOMATIC |
| CLOTHES WASHER FIXTURE DRAIN SHALL |
| CONNECT TO A BRANCH DRAIN OR DRAINAGE |
| STACK A MINIMUM OF 3 INCHES (76MM) IN |
| DIAMETER. |
| |
| (B) 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY |
| TRAPPED. STANDPIPES SHALL |
| EXTEND A MINIMUM OF 18 INCHES (457MM) |
| AND A MAXIMUM OF 42 INCHES (1066MM) |
| ABOVE THE TRAP WEIR. ACCESS SHALL BE |
| PROVIDED TO ALL STANDPIPES AND DRAINS |
| FOR RODDING. |
| NOTE: PLEASE INDICATE WASHING MACHINE STANDPIPE IN THE |
| RESUBMITTED DRAWINGS. |
| |
| (C) 708.3.4 BASE OF STACK. A CLEANOUT |
| SHALL BE PROVIDED AT THE BASE OF EACH |
| WASTE OR SOIL STACK |
| |
| (D) 708.3.5 BUILDING DRAIN AND BUILDING |
| SEWER JUNCTION. THERE SHALL BE A |
| CLEANOUT NEAR THE JUNCTION OF THE |
| BUILDING DRAIN AND THE BUILDING SEWER. |
| |
| (E) 708.7 MINIMUM SIZE. CLEANOUTS SHALL |
| BE THE SAME NOMINAL SIZE AS THE PIPE |
| THEY SERVE UP TO 4 INCHES (102MM) |
| NOTE: CLEANOUT FOR THE WASHING MACHINE SHALL BE THREE |
| INCH (3") |
| |
| (F) 708.9 ACCESS. ACCESS SHALL BE |
| PROVIDED TO ALL CLEANOUTS. |
| NOTE: CLEANOUT FOR THE WASHING MACHINE TO BE LOCATED AT |
| FOUR FEET ABOVE FINNISH FLOOR (4' A.F.F.) |
| |
| END OF COMMENTS: |
| |
| REVIEW BY MIKE PERSON |
| (561) 805-6730 |
| FAX (561) 805-6731 |
| E-MAIL [email protected] |
| UNDER SUPERVISION OF K.STEVENS |
| (561) 805-6721 |