Date |
Text |
2007-04-10 12:56:17 | BUILDING PLAN REVIEW |
| PERMIT: 07030499 |
| ADD: 1039 18TH STREET |
| CONT: DREAMALITIES CONSTRUCTION |
| TEL: (561)842-5500 |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2006 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| REVIEW 1ST |
| ACTION: DENIED |
| |
| 1)--- VERY IMPORTANT STATEMENT --- |
| PLEASE DO NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| 2)BEFORE A PERMIT TO CONSTRUCT, MAY |
| BE ISSUED, IMPACT FEES MUST BE PAID TO |
| PALM BEACH COUNTY. THE ACTUAL PERMIT |
| SET OF PLANS MUST BE STAMPED BY THAT |
| OFFICE, AND A COPY OF THE PAID RECEIPT |
| ATTACHED TO THE PERMIT APPLICATION. |
| PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| 3)FL S S 713.13 |
| NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF |
| THE COURT. |
| NOTE: 713.13(2) |
| IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS |
| NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE |
| RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: |
| 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT |
| THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| |
| 4)WPB AMENDMENTS 108.3*THE VALUE IS LOW. IF IN THE |
| OPINION OF THE BUILDING OFFICIAL THE CLAIMED VALUATION |
| IS UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL |
| BE DENIED. FOR PERMITTING PURPOSES, THE VALUE SHALL |
| INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, |
| INTERIOR FINISH NORMAL SITE WORK, ARCHITECTURAL AND |
| DESIGN FEES. OUR VALUATION REFERENCE IS ICC (BVD), |
| MARSHALL-SWIFT AND MEANS COST ANALYSIS. |
| |
| 5)R802.1.6TRUSS DESIGN DRAWINGS, PREPARED IN |
| CONFORMANCE WITH SEC. R802.1.6.1, SHALL BE PROVIDED TO |
| THE BUILDING OFFICIAL AND APPROVED PRIOR TO |
| INSTALLATION. TRUSS DESIGN DRAWINGS SHALL INCLUDE, AT A |
| MINIMUM, (1) DESIGN WIND SPEED AND EXPOSURE CATETORY |
| (2) SLOPE OR DEPTH, SPAN AND SPACING, (3) LOCATION OF |
| ALL JOINTS (4)REQUIRED BEARING WIDTHS. (5) DESIGN |
| LOADS AS APPLICABLE. (5.1) TOP CHORD LIVE LOAD (5.2) |
| TOP CHORD DEAD LOAD (5.3) BOTTON CHORD LIVE LOAD (5.4) |
| BOTTOM CHORD DEAD LOAD. ETC. |
| |
| 6)R319.1 LOCATION REQUIRED. |
| IN AREAS SUBJECT TO DECAY DAMAGE AS ESTABLISHED BY |
| TABLE R301.2(1) , THE FOLLOWING LOCATIONS SHALL REQUIRE |
| THE USE OF AN APPROVED SPECIES AND GRADE OF LUMBER, |
| PRESSURE TREATED IN ACCORDANCE WITH AWPA C1, C2, C3, |
| C4, C9, C15, C18, C22, C23, C24, C28, C31, C33, P1, P2 |
| AND P3, OR DECAY -RESISTANT HEARTWOOD OF REDWOOD, BLACK |
| LOCUST, OR CEDARS. (1)WOOD JOISTS OR THE BOTTOM OF A |
| WOOD STRUCTURAL FLOOR WHEN CLOSER THAN 18 INCHES (457 |
| MM) OR WOOD GIRDERS WHEN CLOSER THAN 12 INCHES (305 MM) |
| TO THE EXPOSED GROUND IN CRAWL SPACES OR UNEXCAVATED |
| AREA LOCATED WITHIN THE PERIPHERY OF THE BUILDING |
| FOUNDATION. |
| (2)ALL WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR |
| MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8 |
| INCHES (203 MM) FROM THE EXPOSED GROUND. (5)WOOD |
| SIDING, SHEATHING AND WALL FRAMING ON THE EXTERIOR OF A |
| BUILDING HAVING A CLEARANCE OF LESS THAN 6 INCHES (152 |
| MM) FROM THE GROUND. |
| |
| 7)106.3.3* PRODUCT APPROVALS- 2004 |
| THOSE PRODUCTS THAT ARE RGULATED BY DCA |
| RULE 9B-72 SHALL BE REVIEWED AND |
| APPROVED IN WRITTING BY THE DESIGNER OF |
| RECORD PRIOR TO SUBMITTAL FOR |
| JURISDICTIONAL APPROVAL. PROVIDE THE STATE COVER SHEET |
| FOR THE PRODUCT APPROVALS. |
| |
| 8)THE ENERGY CALCULATION SHEETS ARE NOT LEGIBLE. |
| PROVIDE CLEAR AND LEGIBLE INFORMATION. SEE NEW FORMS IN |
| PACKAGE. |
| |
| MYRON JACOBS |
| BUILDING PLAN REVIEWER |
| 805-6726 |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |