2007-03-13 14:33:40DENIED BY BUILDING
  
 1) RAS 150 IS NOT ACCEPTED IN THIS JURISDICTION. ALSO,
 THE CITY OF WEST PALM BEACH IS NOT LOCATED IN THE HIGH
 VELOCITY HURRICANE ZONE.
  
 2) THE SYSTEM SPECIFIED IN THE NOA IS FOR A WOOD
 NON-INSULATED DECK. ON SOME OF THE PAPER WORK THAT WAS
 SUBMITTED 3/4" PERLITE INSULATION IS SPECIFIED. IF THE
 DECK WILL BE INSULATED,SELECT A SYSTEM FOR AN
 INSULATED WOOD DECK FROM THE NOA.
  
 3) THE MAXIMUM DESIGN PRESSURE SPECIFIED FOR THE
 ROOFING MATERIAL, ON PAGE 28 OF THE NOA, IS TOO LOW FOR
 ROOF ZONE 3 (- 89 PSF) . SEE 2004 FBC TABLE
 1609.6.2.1(2). GENERAL LIMITATION #7 ON PAGE 32 OF THE
 NOA ALLOWS THE PRESSURE TO BE INCREASED BASED ON
 ENHANCED FASTENER SPACING CALCULATED USING RAS 117.
 SUBMIT RAS 117 CALCULATIONS.
  
 ROBERT MCDOUGAL