2007-04-02 09:17:23BUILDING PLAN REVIEW
 PERMIT: 07030127
 ADD: 1400 CENTREPARK BLVD
 CONT: PASS INTERNATIONAL, INC
 TEL: (561)954-9000
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 1STREVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2 ) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF
 THE COURT.
 NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS
 NOT ACTUALLY
 COMMENCED WITHIN 90 DAYS AFTER THE RECORDING THEREOF,
 SUCH NOTICE IS
 NULL & VOID. NOTE: 713.13(6)THE POSTING OF THE NOTICE
 OF COMMENCEMENT
 AT THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3) COVERSHEET PROJECT DATA: THE PLANS INDICATE THIS IS
 A TYPE IABUILDING.THIS BUILDING BY THE MINIMUM
 STANDARDS OF THE 2006 FBC IS CONSIDERED A TYPE IB
 BUILDING .
 THE OTHER ISSUE WITH THE BUILDING RATING OF
 "UNPROTECTED" SEE TABLE 601 FOR A TYPE IB BUILDING
 COLUMNS AND FLOORS ARE A MINIMUM OF 2 HR FIRE
 RATINGALSO SEE FOOTNOTE "B".
  
 4)PLANS SUBMITTED AFTER DEC. 8TH, 2006 WILL BE
 REVIEWED UNDER THE 2006 FBC NOT THE 2004 FBC.
  
 5)SHEET A-2 DETAIL "A" BREAK ROOM SINK: INDICATES
 DOORS/ FLOOR WITHIN THE BASE CABINET:
 DOORS AND SHELVING AND FLOOR OF THE SINK BASE CABINET
 TO BE REMOVED FOR FRONTAL APPROACH.
 SINKS:
 11-4.24.2 SINKS, HEIGHT. SINKS SHALL
 BE MOUNTED WITH THE COUNTER NO HIGHER
 THAN 34" ABOVE THE FINISH FLOOR.
 11-4.24.3 KNEE CLEARANCE THAT IS AT
 LEAST 27" HIGH 30" WIDE, AND 19" DEEP
 SHALL BE PROVIDED UNDERNEATH SINKS.
 11-4.24.5 CLEAR FLOOR SPACE.
 A CLEAR FLOOR SPACE AT LEAST 30 INCHES BY 48 INCHES
 (760 MM BY 1219 MM) COMPLYING WITH SECTION 11-4.2.4
 SHALL BE PROVIDED IN FRONT OF A SINK TO ALLOW FORWARD
 APPROACH. THE CLEAR FLOOR SPACE SHALL BE ON AN
 ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 19
 INCHES (485 MM) UNDERNEATH THE SINK.
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  
  


Account Summary | Usage Policy | Privacy Policy