Plan Review Notes For Permit 07030070 |
Permit Number |
07030070 |
|
Review Stop |
B |
Sequence Number |
3 |
|
Notes |
Date |
Text |
2007-07-27 10:01:23 | BUILDING REVIEW APPROVED WITH PROVISO: | | 1- ARCHITECT TO PROVIDE BUILDING CONSTRUCTION TYPE ON | | SHEET T1 AND A4 AS REQUIRED BY SEC. 602.1OF FBC | | 2004. | | 2- PROVIDE REVISED DRAINAGE PLAN SHOWING WATER BEING | | DIVERTED AWAY FROM NEIGHBOR'S PROPERTY. | | 3- REVISE TYPE OF NAIL USED FOR ROOF SHEATHING. NEED | | "RING SHANK NAILS" AS REQUIRED BY SEC. R803.2.3.12004 | | FLORIDA RESIDENTIAL CODE. | | 4- SOIL TEST REPORT NEED TO HAVE THE CERTIFICATEOF | | AUTHORIZATION NUMBER AS REQUIRED BY SEC. 61G15-23.002 | | FLORIDA ADMINISTRATIVE CODE. | | 5- ARCHITECT TO REVIEW AND APPROVE IN WRITING PRODUCT | | APPROVAL SUBMITED FOR: | | A) ALUMINUM SLIDING GLASS DOORS NOA 05-1121.08. | | ARCHITECT APPROVED THE FLORIDA PRODUCT APPROVAL COVER | | PAGE FL2038, BUT NOA AND FLORIDA APPROVAL DON'T | | CORRESPOND TO EACH OTHER. | | B) 8" PRECAST LINTELS. SAME THING FROM PREVIOUS | | COMMENT. NOA AND FLORIDA APPROVAL DON'T CORRESPOND TO | | EACH OTHER. |
|