2007-03-27 11:15:38****************PROVISO****************
 A} IF DRYER ROOM IS A CONFINED SPACE, OPENINGS
 REQUIRED PER SECTION 304.5 ORSECTION 304.6 SHALL BE
 INSTALLED.MINIMUM 1,300 CUBIC FEET REQUIRED.
  
 B}FUTURE GENERATOR GAS PIPING AT OWN RISK, SEPERATE
 GEN/RES PERMIT REQUIRED WITH ZONING APPROVAL OF
 GENERATOR PLACEMENT.
 NOTE: PER FBC-2004 FUEL GAS SECTION, 404.12 OUTLET
 CLOSURES. GAS OUTLETS THAT DO NOT CONNECT TO APPLIANCES
 SHALL BE CAPPED GAS TIGHT. IF GAS DELIVERY PRESSURE IS
 2 PSI OR GREATER MP REGULATORS SHALL BE INSTALLED PRIOR
 TO FINAL INSPECTION.