2007-03-30 09:11:42 | BUILDING PLAN REVIEW |
| PERMIT: 07020640 |
| ADD: 250 S. AUSTRALIAN AVE. # 100 |
| CONT: FISHER CONTRACTING CORP |
| TEL: (561) 691-4716 |
| |
| |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2006 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| REVIEW |
| ACTION: DENIED |
| |
| 1)--- VERY IMPORTANT STATEMENT --- |
| PLEASE DO NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| 2 ) FL S S 713.13 |
| NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF |
| THE COURT. |
| NOTE: 713.13(2) |
| IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS |
| NOT ACTUALLY |
| COMMENCED WITHIN 90 DAYS AFTER THE RECORDING THEREOF, |
| SUCH NOTICE IS |
| NULL & VOID. NOTE: 713.13(6)THE POSTING OF THE NOTICE |
| OF COMMENCEMENT |
| AT THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| |
| 3) SHEET A4.1 SERVING LINE DETAIL INDICATES A CUT |
| SECTION5 & 6 OF A1.1 IN NEATHER SECTION IS THE HEIGHT |
| OF THE SERVING COUNTER PROVIDED. |
| 11-5.2 COUNTERS AND BARS. |
| WHERE FOOD OR DRINK IS SERVED AT COUNTERS EXCEEDING 34 |
| INCHES (865 MM) IN HEIGHT FOR CONSUMPTION BY CUSTOMERS |
| SEATED ON STOOLS OR STANDING AT THE COUNTER, A PORTION |
| OF THE MAIN COUNTER WHICH IS 60 INCHES (1525 MM) IN |
| LENGTH MINIMUM SHALL BE PROVIDED IN COMPLIANCE WITH |
| SECTION 11-4.32 OR SERVICE SHALL BE AVAILABLE AT |
| ACCESSIBLE TABLES WITHIN THE SAME AREA. |
| |
| 3B) ALSO SEE THE COUNTER HEIGTH OF THE ISLAND A1.1 |
| DEETAIL# 9, PLEASE CORRECT. |
| |
| 4) PLEASE INDICATE THE AREAS FOR ACCESSIBLITY. 11-5.1 |
| GENERAL. |
| EXCEPT AS SPECIFIED OR MODIFIED IN THIS SECTION, |
| RESTAURANTS AND CAFETERIAS SHALL COMPLY WITH THE |
| REQUIREMENTS OF SECTION 11-4.1 TO SECTION 11-4.35 . |
| WHERE FIXED TABLES (OR DINING COUNTERS WHERE FOOD IS |
| CONSUMED BUT THERE IS NO SERVICE) ARE PROVIDED, AT |
| LEAST 5 PERCENT, BUT NOT LESS THAN ONE, OF THE FIXED |
| TABLES (OR A PORTION OF THE DINING COUNTER) SHALL BE |
| ACCESSIBLE AND SHALL COMPLY WITH SECTION 11-4.32 AS |
| REQUIRED IN SECTION 11-4.1.3 (18). IN ESTABLISHMENTS |
| WHERE SEPARATE AREAS ARE DESIGNATED FOR SMOKING AND |
| NONSMOKING PATRONS, THE REQUIRED NUMBER OF ACCESSIBLE |
| FIXED TABLES (OR COUNTERS) SHALL BE PROPORTIONALLY |
| DISTRIBUTED BETWEEN THE SMOKING AND NONSMOKING AREAS. |
| IN NEW CONSTRUCTION, AND WHERE PRACTICABLE IN |
| ALTERATIONS, ACCESSIBLE FIXED TABLES (OR COUNTERS) |
| SHALL BE DISTRIBUTED THROUGHOUT THE SPACE OR FACILITY. |
| 11-5.2 |
| |
| |
| 5 ) 110.2* W. P. B. ADMINISTRATIVE |
| CODE, INFORMATION THAT IS REQUIRED FOR |
| RECORD KEEPING & FOR CERTIFICATE OF |
| OCCUPANCY: |
| A) THE EDITION OFTHE CODE UNDER WHICH |
| THE PERMIT WAS ISSUED. PLANS SUBMITTED AFTER DEC. 8, |
| 2006 ARE TO BE REVIEWED UNDER FBC 2006 AMENDMEENTS |
| NOTE ALSO TO BE REVIEWED UNDER THE 2006 FBC EXISTING |
| BUILDING CODE, PROVIDE LEVEL OF ALTERATION |
| B) THE USE AND OCCUPANCY, IN ACCORDANCE |
| WITH THE PROVISIONS OF CHAPTER 3. |
| C) THE TYPE OF CONSTRUCTION AS DEFINED |
| IN CHAPTER 6, TABLE 601. |
| D) THE DESIGN OCCUPANT LOAD, SEE 1004. |
| E) IF AN AUTOMATIC SPRINKLER SYSTEM IS |
| PROVIDED, WHETHER THE SPRINKLER SYSTEM |
| IS REQUIRED. |
| F) ANY SPECIAL STIPULATIONS & CONDITIONS |
| OF THE BUILDING PERMIT. |
| |
| BUILDING PLAN REVIEW |