Date |
Text |
2007-07-03 10:05:48 | DENIED |
| REFERENCE: |
| ** FBC-2004 PLUMBING. |
| ** FBC-2004 CHAPTER 1, THE CITY OF |
| WEST PALM BEACH AMENDMENTS. |
| ** FLORIDA ADMINISTRATIVE CODE. |
| ** FLORIDA STATUTES. |
| |
| ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL |
| IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS, |
| SOME BASED ON PLANS NOW SUBMITTED, NEW DOCUMENTS BEING |
| REVIEWED FOR THE FIRST TIME AND SOME NEW COMMENTS NOT |
| MADE ON PREVIOUS REVIEWS. |
| |
| ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM |
| PREVIOUS REVIEW WITH A NO, OK OR A NO/OK. |
| THESE WILL BE FOR THE EXACT NUMERICAL NOTATION OF THE |
| PREVIOUS REVIEW NOTES. |
| |
| A **NO** IS IF THE COMMENT WAS NOT FULLY ADDRESSED |
| AND/OR FURTHER EXPLANATION OR CHANGES IN PLANS OR |
| DOCUMENTS ARE STILL NEEDED. THIS REVIEWER WILL TRY TO |
| BETTER EXPLAIN NOTE ABOVE PREVIOUS REVIEW COMMENT. |
| |
| AN **OK** WILL BE LABELED AS SUCH ON THE SAME NUMERICAL |
| COMMENT AND WILL HAVE OLD NOTE REMOVED FROM COMMENTS. |
| |
| A **NO/OK** MEANS PART OF THE COMMENT MAY HAVE BEEN |
| ADDRESSED, HOWEVER NOT ALL OF THE PREVIOUS REVIEW |
| COMMENT MAY HAVE BEEN FULLY ADDRESSED. |
| |
| ** PLEASE SEE ANY NEW NOTES WILL BE ADDED TO THE END OF |
| THE PREVIOUS REVIEW COMMENTS AND NOTED AS SUCH. |
| |
| 1. **NO/OK** 1 AUTOMATIC CLOTHES WASHER CONNECTION PER |
| 20 DWELLING UNITS REQUIRED PER TABLE 403.1, MINIMUM |
| NUMBER OF REQUIRED PLUMBING FIXTURES. PLEASE INDICATE |
| THIS CONNECTION ON THE RESUBMITTAL. |
| |
| NOTE: SHEET 2: IS INDICATING A NEW WASHING MACHINE |
| BEING LOCATED OUTSIDE. SHEET 3: IS INDICATING A 2" PVC |
| TO EXISTING SANITARY, PLEASE KNOW THAT THIS IS SIZED |
| WRONG AND THE FOLLOWING INFORMATION IS REQUIRED FOR THE |
| WASHING MACHINE ON THE NEXT RESUBMITTAL. |
| |
| A} PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4 |
| RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A |
| PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING |
| THE WASTE, VENT, TRAP AND SIZES WITH CLEANOUT LOCATIONS |
| OF THE NEW WASHING MACHINE. |
| B} 406.3 WASTE CONNECTIONS.THE TRAP AND FIXTURE DRAIN |
| FOR AN AUTOMATIC CLOTHES |
| WASHER SHALL BE A MINIMUM OF 2 INCHES |
| (51MM) IN DIAMETER. THE AUTOMATIC |
| CLOTHES WASHER FIXTURE DRAIN SHALL |
| CONNECT TO A BRANCH DRAIN OR DRAINAGE |
| STACK A MINIMUM OF 3 INCHES (76MM) IN |
| DIAMETER. |
| C} 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY |
| TRAPPED. STANDPIPES SHALL |
| EXTEND A MINIMUM OF 18 INCHES (457MM) |
| AND A MAXIMUM OF 42 INCHES (1066MM) |
| ABOVE THE TRAP WEIR. ACCESS SHALL BE |
| PROVIDED TO ALL STANDPIPES AND DRAINS |
| FOR RODDING. PLEASE INDICATE THE WASHING MACHINE |
| STANDPIPE ON THE RESUBMITTAL. |
| D} 708.7 MINIMUM SIZE. CLEANOUTS SHALL |
| BE THE SAME NOMINAL SIZE AS THE PIPE |
| THEY SERVE UP TO 4 INCHES (102MM). THE CLEANOUT FOR THE |
| WASHING MACHINE SHALL BE THREE INCH (3") PLEASE |
| INDICATE THIS ON THE RESUBMITTAL. |
| E} 708.9 ACCESS. ACCESS SHALL BE |
| PROVIDED TO ALL CLEANOUTS. PLEASE INDICATE THE CLEANOUT |
| FOR THE WASHING MACHINE AT FOUR FEET ABOVE FINNISH |
| FLOOR (4' A.F.F.) ON THE RESUBMITTAL. |
| |
| 2. **OK** |
| |
| END OF COMMENTS: |
| |
| REVIEW BY MIKE PERSON |
| PLUMBING PLANS EXAMINER |
| (561) 805-6730 |
| FAX (561) 805-6731 |
| E-MAIL [email protected] |
| |