Date |
Text |
2007-04-14 07:36:04 | |
| |
| DENIED |
| |
| |
| 1)BEFORE FURTHER PLAN REVIEW ALL FEES DUE ARE |
| REQUIRED TO BE PAID IN FULL. |
| |
| 2)IN AREAS OF QUESTIONABLE SOILS AS SHOWN IN THE |
| OFFICIAL ZONING MAP OF THE CITY OF WEST PALM BEACH, 2 |
| COPIES OF A SOIL TEST REPORT SHALL BE SUBMITTED PER |
| R401.4 BC RES. |
| |
| 3)PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN |
| COMPLIANCE WITH THE REQUIREMENTS OF R401.3 BC RES. BE |
| SURE TO CREATE SWALES SO NOT TO DRAIN ON TO ADJACENT |
| PROPERTY |
| |
| 4)PROVIDE NOTE ON DRAWINGS THAT TERMITE TREATMENT IS |
| REQUIRED ON ALL EXTERIOR CONCRETE WITHIN 1 FOOT OF |
| PRIMARY STRUCTURE PER 1816.1.6 OR R320.1.6 FBC |
| |
| 5)PROVIDE 2 COPIES OF CURRENT SURVEY SHOWING PROPOSED |
| WORK AND ALL REQUIRED SETBACKS |
| |
| 6)SUBMIT ENERGY CALC'S PER 13-101.2.2 |
| FBC. BE SURE THAT THEY ARE SIGNED AND |
| DATED BY PRUEPARER AND OWNER/AGENT PRIOR |
| TO SUBMITTABLE |
| |
| 7)PROVIDE ATTIC ACCESS ON DRAWINGS TO ALL AREAS AS |
| REQUIRED PER R807.1 FBC RES. |
| |
| 8)ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME, |
| ADDRESS, AND LICENSE NUMBER ON EACH SHEET THAT BEARS |
| THEIR SEAL PER |
| 61G15-23.002(2)PLEASE NOTE ENGINEER IS REQUIRED TO |
| SIGN NOT USE STAMP PER FBPE |
| |
| 9)THE FOLLOWING STRUCTURAL DETAILS REQUIRE |
| CORRECTION; |
| |
| A) THE TIE BEAM AND CB 16 BEAMS ON SECTION 07/S7 ARE |
| NOT DESIGNATED ON PLAN S-2 |
| B) PLAN S-2 THE SECTIONS LABELED A/S7 SHOULD BE THE |
| TYPICAL TRUSS BEARING DETAIL A/S6 |
| C) PROVIDE DETAIL OF KNEE WALL ATTACHMENT TO ROOF |
| TRUSSES |
| D) MAKE CORRECTIONS FOR SECTIONS ON S-3 |
| E) PROVIDE SCHEDULE FOR PRE CAST LINTEL THAT WILL BE |
| USED AND OPENING SIZES TO COMPLY WITH 2104.1.5 FBC |
| |
| 10)PLEASE NOTE THAT ROUGH OPENING SIZES IN THE DOOR |
| AND WINDOW SCHEDULES DO NOT ACCOUNT FOR THE ARCHED |
| TRANSOMS |
| |
| 11)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF |
| EACH PRODUCT APPROVAL THAT |
| IS RELEVANT PER 9B-72. THESE SHOULD INCLUDE THE FLORIDA |
| STATE APPROVAL COVER PAGES, AND THE PRODUCT NOAH THAT |
| LISTS THE SYSTEM COMPONENTS/ FASTENER LIST PAGES, THE |
| PAGES WITH THE CHOSEN ASSEMBLY/ SYSTEM TO BE USED AND |
| THE GENERAL LIMITATIONS PAGE. ALL CAN BE FOUND ON |
| WWW.FLORIDABUILDING.ORG |
| |
| 12)THOSE PRODUCTS WHICH ARE REGULATED BY DC RULE |
| 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR |
| JURISDICTIONAL APPROVAL PER 106.3.3 FBC* |
| |
| 13 )THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA |
| STATE PRODUCT APPROVAL COVER |
| SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON |
| WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT |
| SUBMITTED APPLICATIONS WILL BE DENIED |
| |
| 14)THE FOLLOWING PRODUCT APPROVALS WERE NOT |
| SUBMITTED, PRECAST LINTELS, ENTRY DOORS, CASEMENT |
| WINDOWS AND MULLIONS |
| |
| 15)THE FOLLOWING CORRECTION ARE REQUIRED FOR THE |
| PRODUCT APPROVALS: |
| A) PROVIDE THE MODEL FOR THE GARAGE DOOR (NOT ALL |
| MODELS MEET THE DESIGN PRESSURE) |
| B) PROVIDE THE ROOF SYSTEM FROM THE MODIFIED PRODUCT |
| APPROVAL THAT WILL BE USED |
| C) PLEASE NOTE THE ATTACHMENT METHODS IN THE ROOF TILE |
| PRODUCT APPROVAL ONLY SEVERAL WILL WORK IF YOU ARE |
| USING POLYFOAM A PRODUCT APPROVAL IS REQUIRED |
| D) FOR YOUR INFORMATION I HAVE ATTACHED THE FLORIDA |
| COVER SHEETS TO THE PRODUCT APPROVAL FOR THE PGT FRENCH |
| DOORS (THESE ARE REQUIRED FOR ALL PRODUCT APPROVALS) |
| |
| |
| |
| |
| |
| 16)A RECORDED COPY OF THE NOTICE OF |
| COMMENCEMENT IS REQUIRED PRIOR TO |
| A PERMIT BEING ISSUED |
| |
| |
| BLDG PLAN REVIEW |