Plan Review Notes
Plan Review Notes For Permit 07020355
Permit Number 07020355
Review Stop B
Sequence Number 1
Notes
Date Text
2007-04-03 08:00:26****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC
 FLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)ALL INFORMATION REQUIRED BY FAC61G1-16-23.002, 003
 AND FAC61G15-23.002 ARE TO BE ON EACH SHEET.
  
 2.)ALL SHEETS ARE TO BE SIGNED, SEALED, DATED, FS471,
 FS481 WHEN SUBMITTED FOR PUBLIC RECORD.
  
 3.)DECLARE GOVERNING CODE.
  
 4.)INFORMATIONAL ONLY; THIS IS A PLAN CHECK.PERMIT
 APPLICATON REQUIRED.REVIEW WILL REMAIN IN "F"
 STATUS.
  
 5.)L3, SHOW TRAVEL DISTANCES AND PROVIDE A CODE
 SUMMARY (BUILDING TYPE, OCCUPANCY, TRAVEL DISTANCE,
 BUILDING AREA, OCCUPANT LOAD).
  
 6.)PLATFORM DETAIL EL X-1,2, V13, NO GUARDS SHOWN
 FBC1012.THIS COMMENT APPLIES TO OTHER SHEETS SUCH AS
 EL X-3,4.NOTE THAT THE "HANDRAIL" PLAN DOES NOT HAVE
 CROSS SECTIONS REFERRING TO THESE ELEVATIONS SO I
 CANNOT DETERMINE IF THE HANDRAIL (WHICH MAY ALSO SERVE
 AS GUARDRAILS?) IS TO BE INSTALLED IN THIS LOCATION AND
 WAS OMITTED FOR CLARITY, OR IF THE DESIGN INTENT IS FOR
 THE PLATFORM OPEN SIDES.SEE FBC1012.1, FBC1028.
  
 7.)SHOW ALL REQUIRED GUARDS ON THE PLAN.FOR
 INSTANCE, SEE ELEVATIONS X-3,4.SEE FBC1012, 1028.
  
 8.)ARE ALL HANDRAILS SHOWN ON L1 TO ALSO SERVE AS
 GUARDRAILS?THEY APPEAR TO BE AT PLATFORM AREAS;
 HANDRAILS ARE NOT REQUIRED FOR PLATFORMS BUT GUARDS
 (GUARDRAILS) ARE.SEE OTHER COMMENTS.
  
 9.)SEE ELEVATIONS X-1,2, SECTION DETAIL V7, 3.1. THIS
 DETAIL IS TOO SMALL TO READ.THE SHEETS ARE LABELED
 BUT NOT NUMBERED.DOES THIS REFER TO SHEET 3.1 (NO 3.1
 IN THE SET)?ARCHITECTURAL STANDARDS ARE FOR DETAIL
 AND SECTION INDICATORS TO REFER TO DETAIL AND PAGE, BUT
 THE DETAILS PROVIDED REFER TO SHEETS WHICH ARE NOT IN
 THE PACKAGE.PLEASE EITHER PROVIDE STANDARD DETAIL AND
 SECTION INDICATORS OR ADVISE AS TO HOW I COULD BEST
 UNDERSTAND THE PLAN.
  
 10.) CONTRACTOR HAS DECLARED VALUE OF $45,000.THIS IS
 TO INCLUDE ALL MATERIALS AND LABOR, FBC*108.3.
  
 11.)PLEASE CLARIFY THE PURPOSE OF THE WALKS AND
 LANDINGS.FROM ISO AND ELEVATIONS THIS APPEARS TO BE
 AN OCCUPIABLE WORK AREA, BUT DOES NOT MEET GENERAL
 EGRESS REQUIREMENTS OF FBC10 OR ACCESSIBILITY FBC11
 (VERTICAL ACCESSIBILITY, HANDRAILS, EGRESS, ETC.).SEE
 ALSO FBC11-4.1.3(5)(3) IF APPLICABLE.
  
  