Plan Review Notes
Plan Review Notes For Permit 07020267
Permit Number 07020267
Review Stop M
Sequence Number 4
Notes
Date Text
2008-05-22 13:49:20PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 MECHANICAL REVISION PG. M-1 AND M-2.
  
 *** DENIED ***
 1)A/C SYSTEM #1 MODEL NUMBERS (C/U 2TTA0072 A/H
 TWE063P13) LISTED ON THE A/C EQUIPMENT SCHEDULE COULD
 NOT BE FOUND ON THE ARI DIRECTORY WEB-SITE, PLEASE
 CORRECT OR SUBMIT AN ARI CERTIFICATE, SEE 2004 FBC
 13-407.1.ABC.3.1.1.
  
 2) FLEX DUCT FROM AC-1 TO 10X10 OUTSIDE AIR DUCT NEEDS
 TO BE SIZED, PER 2004 FBC/M 106.3.3.
  
 3) PROVIDE OUTDOOR AIR CALCULATION, PER 2004 FBC/M
 403.2.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]