2007-02-22 18:47:47 | *****DENIED***** |
| |
| |
| 01.THE ACTUAL ADDRESS OF WHERE THE SCOPE OF WORK WILL |
| BE CONDUCTED SHALL BE IN THE TITLE BLOCK OF EACH |
| SUBMITTED PLAN SHEET.THE CORRECT ADDRESS FOR THIS |
| LOCALE IS 600 SOUTH DIXIE HIGHWAY - SUITE 103. |
| |
| 02.ON SHEET 1, THE MENTIONED CODE OF 2003 NFPA 101 IS |
| CORRECT.HOWEVER, ROOM FINISH NOTE #8INCORRECTLY |
| REFERENCES 2005 NFPA 101. |
| |
| 03.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS |
| SHALL BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT |
| OR MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. |
| |
| 04.THE DEMOLITION OF EXISTING AND/OR THE STOCKING OF |
| NEW BUILDING MATERIALS & SUPPLIES SHALL NOT INTERFERE |
| OR HINDER WITH EMERGENCY ACCESS RESPONSE TO THE |
| STRUCTURE OR THE VICINITY THEREOF (INCLUDING FIRE |
| LANES). |
| |
| 05.PROVIDE A LIFE SAFETY PLAN SHEET WHICH INDICATES |
| THE TRAVEL DISTANCE TO THE EXITS. THIS SHEET MAY ALSO |
| INCLUDE THE LOCATION OF EXIT LIGHTS, EMERGENCY LIGHTS, |
| FIRE EXTINGUISHERS,FIRE ALARM DEVICES, AND FIRE |
| SPRINKLERS APPLICABLE TO THE PROPOSED STRUCTURE. |
| |
| 06.SHOW/DISPLAY THESUITE NUMBER ON THE EXTERIOR |
| ELEVATION SO THAT THIS TENANT SPACE IS DISTINGUISHABLE |
| FROM THE OTHER SUITES.AS PER WEST PALM BEACH CODE, |
| THOSE NUMBERS SHALL BE NO LESS THAN 3" IN HEIGHT AND NO |
| LESS THAN 1" IN WIDTH. |
| |
| 07.IT IS NOTED ON SHEET 1 THAT DOOR #25 IS NOT A |
| REQUIRED EXIT DOOR, HOWEVER SHEET 2 HAS IT LABELED AS |
| AN EXIT DOOR.PLEASE EXPLAIN THIS DOOR AND WHERE IT |
| WOULD LEAD PEOPLE. |
| |
| 08.IF SO EQUIPPED WITH A FIRE ALARM SYSTEM, WILL IT |
| BE INDEPENDANT OR WILL IT BE TIED INTO THE PRADO |
| CONDOMINIUM'S SYSTEM. |
| |
| |
| TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE |
| SHEET INDICATING HOW/WHERE ON THE PLANS EACH COMMENT |
| WAS ADDRESSED. |
| |
| |