Plan Review Notes
Plan Review Notes For Permit 07020267
Permit Number 07020267
Review Stop B
Sequence Number 1
Notes
Date Text
2007-02-15 16:31:20BUILDING PLAN REVIEW
 PERMIT:
 ADD:
 CONT:
 TEL: (561)###-####
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2)FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF
 THE COURT.
 NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS
 NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE
 RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE:
 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT
 THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 3)110.2* W. P. B. ADMINISTRATIVE
 CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF
 OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PERMIT WAS ISSUED. FBC 2004 WITH 2006 REVISIONS
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601.
 D) THE DESIGN OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 F) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT.
 -------------------------------------
 ) NUMBER OF UNITS
 ) NUMBER OF FLOORS
 ) NUMBER OF ROOMS
 ) SQ. FT. FOOTPRINT
 ) SQ. FT. UNDER ROOF (TOTAL)
 ) OCCUPANT LOAD
 ) FLOOD ZONE
 ) FLOOD ELEVATION
 )L.O.M.R.
  
 4)THE VALUE ON THE APPLICATION IS LOW.108.3*IF,
 IN THE OPINION OF THE BUILDING OFFICIAL, THE CLAIMED
 VALUATION OF BUILDING, ALTERATION. STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDERESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC,
 PLUMBING, MECHANICAL, INTERIOR FINISH, ARCHITECTURAL
 AND DESIGN FEES, MARKETING COST, OVERHEAD AND PROFIT;
 EXCLUDING LAND ONLY. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS
 SERVICES.
  
 5)FBC 106.3.5.1.1SUBMIT A LIFE SAFETY PLAN SHOWING
 THE MEANS OF EGRESS AND TRAVEL DISTANCE. IS THERE A
 SPRINKLER SYSTEM IN THIS AREA?CLARIFY.
  
 6)FBC 11-7.2(2) (I) A PORTION OF THE MAIN COUNTER
 WHICH IS A MINIMUM OF 36 INCHES IN LENGTH SHALL BE
 PROVIDED WITH A MAXIMUM HEIGHT OF 36 INCHES.IN NEW
 CONSTRUCTION, WHERE THE SELLING SPACE IS UNDER 5,000
 SQUARE FEET, ONLY ONE CHECK-OUT AISLE IS REQUIRED TEO
 BE ACCESSIBLE. SHOW COMPLIANCE WITH ELEVATION
 DRAWINGS.
  
 7)FBC.11-5.2 WHERE FOOD OR DRINKIS SERVED AT
 COUNTERS EXCEEDING 34 INCHES IN HEIGHT FOR CONSUMPTION
 BY COUSTOMERS SEATED ON STOOLS OR STANDING AT THE
 COUNTER, A PORTION OF THE MAIN COUNTERWHICH IS60
 INCHES IN LENGTH MINIMUM SHALL BE PROVIDED IN
 COMPLIANCE WITH SECTION 11-4.32 OR SERVICES SHALL BE
 AVAILABLE AT TABLES WITHIN THE SAME AREA.
  
 8)CLARIFY IF THE BUILDING OR NEW SPACE HAS A
 SPRINKLER SYSTEM, AND IF IT DOES, STATE THE TYPE OF
 SPRINKLER SYSTEM ON THE DRAWINGS. SEE SHEET 1.
  
 9)SHOWER STALLS SHALL COMPPLY WITH SECTION 11-4.21
 PROVIDE AN ELEVATION DRAWINGS WITH ALL THE DIMENTIONS.
  
 10)FBC 1210.3 SHOWER COMPARTMENTS AND WALLS ABOVE
 BATHBUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED
 WITH A SMOOTH, NONABSORBENT SURFACE TO A HEIGHT NOT
 LESS THAN 70 INCHES ABOVE THE DRAIN INLET.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  