2007-03-21 18:54:48 | BUILDING REVIEWCHECKLIST: |
| 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC 713.13 |
| FLORIDA STATUTE. |
| |
| 2- BRING PLANS TO PALM BEACH COUNTY FOR IMPACT FEES. |
| BRING BACK STAMPED PLANS AND COPY OF PAID RECEIPT. |
| ***NOTE: MAKE SURE CORRECT BUILDING AREA IS SHOWN ON |
| PLANS. |
| |
| 3- SHEET A-1.0: DRIVEWAY APPROACH IS NOT SHOWN |
| CORRECTLY. ALSO, CONTACT ENGINEERING DEPARTMENT AT |
| (561) 494-1040 FOR DRIVEWAY AND APPROACH STANDARDS. |
| |
| 4- ENERGY CALCULATIONS: |
| A) REVISE OVERHANG LENGTH AND HEIGHT. SEE PLANS. |
| |
| B) MAKE SURE A/C AREA MATCHES PLANS. |
| |
| C) COMPLETE ALL INFORMATION ON TOP OF FORM. |
| |
| D) REVISE RAISED WOOD, ADJACENT AREA. SEE PLANS FOR |
| CORRECT INFORMATION. |
| |
| 5- PROVIDE COMPLETE INFORMATION FOR STORM SHUTTERS. |
| PROVIDE PRODUCT APPROVAL AND COMPLETE INSTALLATION |
| SCHEDULE. SEE ATTACHED SAMPLE OF INSTALLATION |
| SCHEDULE. |
| *** NOTE: DESIGNER OF RECORD TO REVIEW AND APPROVE IN |
| WRITING PRODUCT APPROVAL AS REQUIRED BY SEC. 106.3.3 |
| CITY AMENDMENTS TO FBC 2004. |
| |
| 6- BUILDING VALUATION AND RADON FEES WILL BE UPDATED |
| WHEN CORRECT FLOOR AREAS ARE PROVIDED. |
| |
| 7- PROVIDE PRODUCT APPROVAL AS REQUIRED BY RULE 9B-72 |
| FOR: |
| A) ENTRY DOOR WITH IMPACT GLASS AS SPECIFIED ON |
| PLANS. |
| |
| B) ASPHALT SHINGLES.NOA #04-0305.03 EXPIRED ON |
| 02/21/07. |
| |
| C) SINGLE HUNG WINDOWS. NEED LEGIBLE DRAWINGS. |
| |
| D) COLONIAL SHUTTERS SHOWN ON EXTERIOR ELEVATIONS. |
| |
| E) WINDOW MULLIONS. NEED CLEAR AND LEGIBLE |
| DRAWINGS. |
| |
| F) LOUVERS IN GABLE END WALLS. |
| |
| G) REAR AND 2ND FLOOR FRENCH DOORS. |
| |
| 8- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING |
| (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS |
| REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. |
| |
| 9- ARCHITECT TO PROVIDE ALL HIS INFORMATION AND FIRM'S |
| REGISTRATION NUMBERAS REQUIRED BY SEC. 61G1-16.004 OF |
| FLORIDA ADMINISTRATIVE CODE. |
| |
| 10- A) PROVIDE SURVEY WITH PROPOSED BUILDING LAYOUT AND |
| SETBACKS. |
| |
| B) SURVEY TO HAVE ORIGINAL SIGNATURE AS REQUIRED BY |
| CHAPTER 472 FLORIDA STATUTE. |
| |
| 11- SHEET 2.1:SPECIFY TOP AND BOTTOM CONNECTORS FOR |
| 4" WOOD COLUMNS. SEC. 106.1.2 CITY AMENDMENTS TO FBC |
| 2004. |
| |
| 12- SHEET 3.1: |
| A) REVISE PLYWOOD SHEATHING NAILING SCHEDULEAND |
| NOTE REGARDING RING SHANK NAILS. SEE SEC. R803.2.3.1 OF |
| 2004 FLORIDA RESIDENTIAL CODE. |
| |
| B) REVISE SKETCHSHOWING ROOF ZONES.SEE FIGURE |
| R301.2(8) 2004 FLORIDA RESIDENTIAL CODE. |
| |
| C) PROVIDE DETAIL C/3.1 SHOWING CONNECTION OF GABLE |
| END BEAM WITH STEEL CAP. SEC. 106.1.2 CITY AMENDMENT TO |
| FBC 2004. |
| |
| D) CLARIFY WHY USING ONLY ONE LEDGER TO SUPPORT |
| FLOOR TRUSSES. TAKE INTO CONSIDERATION HOW MUCH BEARING |
| IS REQUIRED AT THE END OF TRUSSES AND AT THE END OF |
| GIRDER TRUSSES. SEC. 106.1.2 CITY AMENDMENTS TO FBC |
| 2004. |
| |
| E) PROVIDE DETAIL SHOWING CONNECTION OF FRONT PORCH |
| WOOD BEAM TO CONTINUOUS STEEL COLUMN AT CORNER AREAS. |
| SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. |
| |
| F) SPECIFY HOW LONG ARE THE HILTI EXP.ANCHORS |
| SPECIFIED TO SUPPORT 2X8 JOISTS AT FRONT PORCH. SEC. |
| 106.1.2 CITY AMENDMENTS TO FBC 2004. |
| |
| G) SPECIFY CONNECTORS AT THE ENDS OF 2X8 JOISTS AT |
| FRONT PORCH. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. |
| |
| H) WIND DESIGN INFORMATION ITEM #5: CLARIFY WHY THE |
| INTERNAL PRESSURE COEFFICIENT IS NOT APPLICABLE IF THIS |
| BUILDING IS DESIGNED ASCLOSED?. SEC. 106.1.2 CITY |
| AMENDMENTS TO FBC 2004. |
| |
| I) CLEARLY SPECIFY DESIGN PRESSURES FOR EACH OPENING |
| IN THIS BUILDING. SEC. 106.1.2 CITY AMENDMENTS TO FBC |
| 2004. |
| |
| 13- SHEET 4.1: |
| A) SPECIFY SAFETY GLASS FOR WINDOW NEXT TO THE BATH |
| TUB IN MASTER BATHROOM AS REQUIRED BY SEC. R308.4 OF |
| 2004 FLORIDA RESIDENTIAL CODE |
| |
| B) REVISE ALL AREA CALCULATIONS. |
| |
| 14- SHEET 6.1: REVISE CARDINAL ORIENTATION OF EACH |
| ELEVATION.SEE SURVEY FOR CORRECT BUILDING |
| ORIENTATION. |
| |
| |
| 15- SHEET 7.1 WALL SECTION 2/7.1: CLARIFY TYPE OF ROOF |
| COVERING. SHINGLES OR TILE. REVISE AS REQUIRED. |
| |
| 16- SHEET 9.1: |
| A) PROVIDE COMPLETE STRUCTURAL BUCK DETAIL FOR ALL |
| DOORAND WINDOW TYPES.SEE SEC. R 613.6.2 OF 2004 |
| FLORIDA RESDIENTIAL CODE FOR PROPERINSTALLATION. |
| SPECIFY ALL FASTENERS. ALSO, SEE PRODUCT APPROVALS FOR |
| REQUIRED BUCK SIZE. |
| |
| B) WINDOW F IS NOT AN EGRESS WINDOW. REVISE AS |
| REQUIRED. |
| |
| 16- SOIL TEST REPORT TO HAVE ENGINEERING FIRM |
| CERTIFICATE OF AUTHORIZATION NUMBER IN ALL SHEETS AS |
| REQUIRED BY SEC. 61G15-23.002 FLORIDA ADMINISTRATIVE |
| CODE |
| |