2007-03-12 09:25:21 | BUILDING PLAN REVIEW |
| PERMIT: 07011175 |
| ADD: 1115 13TH ST |
| CONT: ALL-SITE CONSTRUCTION |
| TEL: (561)317-6959 |
| |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2006 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 1STREVIEW |
| ACTION: DENIED |
| |
| 1)--- VERY IMPORTANT STATEMENT --- |
| PLEASE DO NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| 2 ) FL S S 713.13 |
| NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF |
| THE COURT. |
| NOTE: 713.13(2) |
| IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS |
| NOT ACTUALLY |
| COMMENCED WITHIN 90 DAYS AFTER THE RECORDING THEREOF, |
| SUCH NOTICE IS NULL & VOID. |
| NOTE: 713.13(6)THE POSTING OF THE NOTICE OF |
| COMMENCEMENT AT THE CONSTRUCTION |
| SITE BEFORE THE FIRST INSPECTION. |
| |
| 3 ) 110.2* W. P. B. ADMINISTRATIVE |
| CODE, INFORMATION THAT IS REQUIRED FOR |
| |
| RECORD KEEPING & FOR CERTIFICATE OF |
| OCCUPANCY: |
| A) THE EDITION OFTHE CODE UNDER WHICH |
| THE PERMIT WAS ISSUED. |
| NOTE ALSO REFLECT EXISTING BUILDING CODE 2004/2006 |
| AMENDMENTS |
| NOTE CHAPTER 8 FOR CHANGE IN OCCUPANCY |
| NOTE CHAPTER 9 FOR ADDITIONS |
| B) THE USE AND OCCUPANCY, IN ACCORDANCE |
| WITH THE PROVISIONS OF CHAPTER 3.NOTE CHANGE IN |
| OCCUPANCY. |
| C) THE TYPE OF CONSTRUCTION AS DEFINED |
| IN CHAPTER 6, TABLE 601. |
| |
| D) THE DESIGN OCCUPANT LOAD, SEE 1004. |
| E) IF AN AUTOMATIC SPRINKLER SYSTEM IS |
| PROVIDED, WHETHER THE SPRINKLER SYSTEM |
| IS REQUIRED. |
| F) ANY SPECIAL STIPULATIONS & CONDITIONS |
| OF THE BUILDING PERMIT. |
| |
| 4) THE DECLARED VALUE OF THE PROJECT IS LOW IN VALUE. |
| IF THE VALUE OF THE PROJECT IS NOT INCREASED, |
| THE CITY WILL CALCULATE THE COST OF THE PROJECT USING |
| MARSHALL & SWIFT FOR CALCULATING PURPOSES |
| LATEST EDITION. 384 SQ FT X $105.10(ADDITION ALONE)= |
| $40,359.00.I-4 OCCUPANCY / DAYCARE |
| SEE CALCULATED FEES + STATE RADON FEES= FEE BALANCE OF |
| $307.18. |
| |
| 5) A CHANGE IN OCCUPANCY PLUS AN |
| ADDITION IMPACT FEES ASSESSMENT; |
| BEFORE A PERMIT TO CONSTRUCT, MAY |
| BE ISSUED, IMPACT FEES MUST BE PAID TO |
| PALM BEACH COUNTY. THE ACTUAL PERMIT |
| SET OF PLANS MUST BE STAMPED BY THAT |
| OFFICE, AND A COPY OF THE PAID RECEIPT |
| ATTACHED TO THE PERMIT APPLICATION. |
| PLEASE CALL (561)233-5025 FOR MORE |
| INFORMATION. |
| |
| 6) PLANS INDICATE THE USE OF 32" DOORS, THE 32" POCKET |
| DOORS ARE |
| CODE COMPLIANTBUT THE OTHER DOORS THAT ARE A 32" DOOR |
| WILL NOT PROVIDE A 32" OPENING. |
| RESTROOM DOORS:11-4.22.2 DOORS. |
| ALL DOORS TO ACCESSIBLE TOLIET ROOMS SHALL COMPLY WITH |
| 11-4.13. DOORS SHALL NOT SWING INTO |
| CLEAR FLOOR SPACE REQUIRED FOR ANY |
| FIXTURE. |
| 11-4.13.6 MANEUVERING CLEARENCES |
| AT DOORS. MINIMUM MANEUVERING CLEARANCES |
| AT DOORS THAT ARE NOT AUTOMATIC OR |
| POWER-ASSISTED SHALL BE AS SHOWN IN |
| FIG. 25. THE FLOOR OR GROUND AREA WITH |
| IN THE REQUIRED CLEARANCES SHALL BE |
| CLEAR & LEVEL. |
| |
| 7) EXISTING BUILDING CODE, 812.5 ACCESSIBILITY. |
| EXISTING BUILDINGS OR PORTIONS THERREOF THAT UNDERGO A |
| CHANGE IN OCCUPANCY CLASSIFICATION SHALL COMPLY WITH |
| CHAPTER 11 OF THE FLORIDA BUILDING CODE. |
| |
| 8) EXISTING BUILDING CODE 905.1 ACCESSIBILITY |
| PROVISIONS FOR NEW CONSTRUCTION SHALL APPLY TO |
| ADDITIONS. AN ADDITION THAT AFFECTS THE ACCESSIBILITY |
| TO OR CONTAIN AN AREA OF, PRIMARY FUNCTION SHALL COMPLY |
| WITH THE REQUIREMENTS IN CHAPTER 11 OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 9) PLEASE PROVIDE SITE PLAN INDICATING THE HANDICAPPED |
| PARKING AND ACCESSIBLE ROUTE TO THE |
| ENTRY.11-4.1.1(A)(B)/ 11-4.1.2(5)(A). |
| |
| 10)FL BLD CODE 1609.1.4: COMPONENTS & |
| CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| TESTING REPORTS,MISSING REPORTS ARE AS |
| FOLLOWS: |
| A) WINDOWS |
| B) EXTERIOR DOORS |
| C) TRUSS ANCHORS |
| D) LOUVERS |
| E) ROOF ASSEMBLIES |
| |
| 11 PRODUCT APPROVALS SUBMITTED WITH |
| PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| PLEASE SEE THE STATE WEBSITE AT |
| WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| STATEWIDE APPROVAL ARE REQUIRED TO BE |
| SUBMITTED WITH A COVER SHEET THAT LISTS |
| THE PRODUCT IDENTITY NUMBER FROM THE |
| STATE. IF THE PRODUCT DOES NOT HAVE |
| STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| SPECIFIC FORM PER RULE 9B-72. SEE |
| ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| |
| |
| 12)WPB ADMIN CODE 106.3* PRODUCT |
| APPROVALS. THOSE PRODUCT WHICH ARE |
| REGULATED BY DCA RULE 9B-72 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| FOR JURISDICTIONAL APPROVAL. |
| |
| 13) PLANS DO NOT PROVIDE SLOPE OF ROOF PLEASE COMPLY |
| WITH: |
| 1507.2.8 UNDERLAYMENT APPLICATION. |
| FOR ROOF SLOPES FROM TWO UNITS VERTICAL IN 12 UNITS |
| HORIZONTAL (17-PERCENT SLOPE), UP TO FOUR UNITS |
| VERTICAL IN 12 UNITS HORIZONTAL (33-PERCENT SLOPE), |
| UNDERLAYMENT SHALL BE TWO LAYERS APPLIED IN THE |
| FOLLOWING MANNER. APPLY A MINIMUM 19-INCH-WIDE (483 MM) |
| STRIP OF UNDERLAYMENT FELT PARALLEL WITH AND STARTING |
| AT THE EAVES, FASTENED SUFFICIENTLY TO HOLD IN PLACE. |
| STARTING AT THE EAVE, APPLY 36-INCH-WIDE (914 MM) |
| SHEETS OF UNDERLAYMENT OVERLAPPING SUCCESSIVE SHEETS 19 |
| INCHES (483 MM) AND FASTENED SUFFICIENTLY TO HOLD IN |
| PLACE. FOR ROOF SLOPES OF FOUR UNITS VERTICAL IN 12 |
| UNITS HORIZONTAL (33-PERCENT SLOPE) OR GREATER, |
| UNDERLAYMENT SHALL BE ONE LAYER APPLIED IN THE |
| FOLLOWING MANNER. UNDERLAYMENT SHALL BE APPLIED SHINGLE |
| FASHION, PARALLEL TO AND STARTING FROM THE EAVE AND |
| LAPPED 2 INCHES (51 MM), FASTENED ONLY AS NECESSARY TO |
| HOLD IN PLACE. |
| |
| 14) 1203.2 ATTIC SPACES. |
| ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE |
| CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF |
| FRAMING MEMBERS SHALL HAVE CROSS VENTILATION FOR EACH |
| SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED |
| AGAINST THE ENTRANCE OF RAIN. BLOCKING AND BRIDGING |
| SHALL BE ARRANGED SO AS NOT TO INTERFERE WITH THE |
| MOVEMENT OF AIR. A MINIMUM OF 1 INCH (25 MM) OF |
| AIRSPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND |
| THE ROOF SHEATHING. THE NET FREE VENTILATING AREA SHALL |
| NOT BE LESS THAN 1 / 150 OF THE AREA OF THE SPACE |
| VENTILATED, WITH 50 PERCENT OF THE REQUIRED VENTILATING |
| AREA PROVIDED BY VENTILATORS LOCATED IN THE UPPER |
| PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FEET |
| (914 MM) ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE |
| OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE |
| VENTS. |
| |
| BUILDING PLAN REVIEW |