Plan Review Notes For Permit 07010800 |
Permit Number |
07010800 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2007-01-12 19:25:36 | BUILDING REVIEW CHECKLIST: | | 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY | | SEC. 713.13 FLORIDA STATUTES. | | | | 2- FLAT ROOF SYSTEM: | | A) PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS AS | | REQUIRED BY GENERAL LIMITATION #7. SEE PAGE 20 OF NOA | | #06-0613.06 SUBMITTED. | | | | B) NOA SUBMITTEDIS MISSING THE FIRST PAGES WHERE | | ALL THE APPROVED COMPONENTS ARE LISTED. SEE ATTACHED | | COPY OF CITY POLICY FOR ROOFING PERMITS. | | | | 3- NOA #06-0424.03 SUBMITTED FOR POLISTICK TU PLUS IS | | SUPERSEDED ACCORDING TO THE MIAMI DADE COUNTY WEBSITE. | | NEED TO PROVIDE CURRENT NOA. | | | | 4- IFTHERE IS ANY MECHANICAL EQUIPMENT ON THE ROOF, | | THEN SEPARATE MECHANICAL PERMIT IS REQUIRED. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|