2007-02-26 10:55:13 | BUILDING PLAN REVIEW |
| PERMIT: 07010734 |
| ADD:229 SANTA LUCIA DR. |
| CONT: TREND WEST, INC. |
| TEL: (561)547-2944 |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2006 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| REVIEW 1ST |
| ACTION: DENIED |
| |
| 1)--- VERY IMPORTANT STATEMENT --- |
| PLEASE DO NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| 2)PROVIDE A WALL SECTION FRAMING DETAIL OF THE NEW |
| 2X6 WALL. SHOW THE ELEVATION DRAWINGS WITH THE FRAMING |
| DETAILS FOR THE DOOR AND WINDOWS OPENINGS. ALSO SHOW |
| THE CONNECTION OF THE TOP AND BOTTOM PLATES. |
| |
| 3)WPB AMENDMENTS 108.3*IF IN THE OPINION OF THE |
| BUILDING OF THE BUILDING OFFICIAL, THE CLAIMED |
| VALUATION OF BUILDING, ALTERATION, STRUCTURE, |
| ELECTRICAL, GAS MECHANICAL OR PLUMBING SYSTEMS APPEARS |
| TO BE UNDERESTIMATED ON THE APPLICATION, THE PERMIT |
| SHALL BE DENIED. FOR PERMITTING PURPOSES, VALUATION OF |
| BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE |
| TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, MECHANICAL, |
| INTERIOR FINISH, ARCHITECTURAL AND DESIGN FEES.OUR |
| VALUATION REFERENCE IS ICC (BVD), MARSHALL-SWIFT AND |
| MEANS COST ANALYSIS SERVICES. |
| |
| 4)R602.2.3 WOOD STUD WALLS SHALL BE CAPPED WITH A |
| DOUBLE TOP PLATE INSTALLED TO PROVIDE OVERLAPPING AT |
| CORNERS AND INTERSECTIONS WITH BEARING PARTITIONS. |
| PLATES SHALL BE A NOMINAL 2 INCHES IN DEPTH AND HAVE |
| WIDTH AR LEAST EQUAL TO THE WIDTH OF THE STUDS. |
| |
| 5)2004 FL. BLD CODE 1603.1.4 THE |
| FOLLOWING INFORMATION RELATED TO WIND |
| SHALL BE SHOWN ON THE CONSTRUCTION |
| DRAWINGS, |
| 1)- BASIC WIND SPEED, MPH |
| 2)- WIND IMPORTANCE FACTOR, & BUILDING |
| CATEGORY |
| 3)- WIND EXPOSURE |
| 4)- INTERNAL PRESSURE COEFFICIENT, |
| 5)- COMPONENTS & CLADDING, THE DESIGN |
| WIND PRESSURES IN TERMS OF PSF. |
| |
| MYRON JACOBS |
| BUILDING PLAN REVIEWER |
| 805-6726 |
| |
| |
| |
| |
| |