2007-04-05 15:39:25DENIED BY BUILDING
  
 1)104.2.1.3 THE BUILDING OFFICIAL
 MAY SET STANDARDS THROUGH DEPARTMENTAL
 POLICY STANDARDS FOR PLANS AND SPECIFICATIONS. "NO
 WHITE OUT".THE CHANGES THAT WERE MADE ON SHEET G-1 TO
 UPDATE THE EDITION OF ASCE 7 ARE NOT ACCEPTABLE. ANY
 CHANGES TO SEALED DRAWINGS ARE REQUIRED TO BE MADE BY
 THE PERSON THAT SIGNED AND SEALED THOSE DRAWINGS. THE
 ITEM THAT IS CHANGED CAN BE CROSSED OUT BY THE
 ARCHITECT AND CHANGED BUT " WHITE-OUT" CAN NOT BE USED
 OR A NEW CORRECTED SIGNED AND SEALED SHEET CAN BE
 SUBMITTED.
  
 2)THE RESPONSE TO ITEM NUMBER (4) FROM THE PREVIOUS
 REVIEW IS NOT ADEQUATE. 4) PROVIDE A SITE PLAN SHOWING
 COMPLIANCE WITH R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS
 TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO
 DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE
 GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM
 OF 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048
 MM).
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL
 WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE
 PROVIDED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE.
 THE SITE PLAN IS REQUIRED TO SHOW THE FALL IN GRADE
 AWAY FROM THE STRUCTURE AND THE PATH OF THE SURFACE
 WATER TO THE APPROVED COLLECTION POINT. IT IS TO SHOW
 ANY SWALES, DRAINS OR OTHER MEANS USED TO CONTAIN THE
 SURFACE WATER ON THE LOT WITHOUT DIVERTING IT TO THE
 ADJACENT LOTS AND DIRECT IT TO THE APPROVED COLLECTION
 POINT.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
  