Date |
Text |
2007-04-05 15:39:25 | DENIED BY BUILDING |
| |
| 1)104.2.1.3 THE BUILDING OFFICIAL |
| MAY SET STANDARDS THROUGH DEPARTMENTAL |
| POLICY STANDARDS FOR PLANS AND SPECIFICATIONS. "NO |
| WHITE OUT".THE CHANGES THAT WERE MADE ON SHEET G-1 TO |
| UPDATE THE EDITION OF ASCE 7 ARE NOT ACCEPTABLE. ANY |
| CHANGES TO SEALED DRAWINGS ARE REQUIRED TO BE MADE BY |
| THE PERSON THAT SIGNED AND SEALED THOSE DRAWINGS. THE |
| ITEM THAT IS CHANGED CAN BE CROSSED OUT BY THE |
| ARCHITECT AND CHANGED BUT " WHITE-OUT" CAN NOT BE USED |
| OR A NEW CORRECTED SIGNED AND SEALED SHEET CAN BE |
| SUBMITTED. |
| |
| 2)THE RESPONSE TO ITEM NUMBER (4) FROM THE PREVIOUS |
| REVIEW IS NOT ADEQUATE. 4) PROVIDE A SITE PLAN SHOWING |
| COMPLIANCE WITH R401.3 DRAINAGE. |
| SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER |
| CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS |
| TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO |
| DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE |
| GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM |
| OF 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048 |
| MM). |
| EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER |
| PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL |
| WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE |
| PROVIDED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. |
| THE SITE PLAN IS REQUIRED TO SHOW THE FALL IN GRADE |
| AWAY FROM THE STRUCTURE AND THE PATH OF THE SURFACE |
| WATER TO THE APPROVED COLLECTION POINT. IT IS TO SHOW |
| ANY SWALES, DRAINS OR OTHER MEANS USED TO CONTAIN THE |
| SURFACE WATER ON THE LOT WITHOUT DIVERTING IT TO THE |
| ADJACENT LOTS AND DIRECT IT TO THE APPROVED COLLECTION |
| POINT. |
| |
| ROBERT MCDOUGAL |
| BLDG. PLAN REVIEW |
| (561)805-6714 |
| |