Plan Review Notes For Permit 07010630 |
Permit Number |
07010630 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2007-01-10 16:13:03 | BUILDING REVIEW CHECKLIST: | | 1- BERMUDA CONCRETE FLAT ROOF TILE NOA 06-0310.06 FILE | | IS CLOSED ACCORDING TO THE MIAMI DADE COUNTY WEBSITE. | | SEE ATTACHED COPY. NEED TO PROVIDE CURRENT PRODUCT | | APPROVAL. | | | | 2- FLAT ROOF SYSTEM PRODUCT APPROVAL PROVIDED: | | A) PAGE 28 OF NOA 03-0501.02: SPECIFY WHICH | | FASTENING METHOD IS GOING TO BE USED. | | | | B) PROVIDE RAS 117 CALCULATIONS AS REQUIRED BY | | GENERAL LIMITATION #7 ON PAGE 32 OF 32. | | | | C) SPECIFY ON PERMIT APPLICATION SQUARE FOOTAGE FOR | | FLAT ROOF. | | | | 3- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY | | SEC. 713.13 FLORIDA STATUTES. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|