2007-01-31 06:44:21 | BUILDING PLAN REVIEW |
| PERMIT: |
| ADD: |
| CONT: |
| TEL: (561)###-#### |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2006 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| REVIEW |
| ACTION: DENIED |
| |
| 1)--- VERY IMPORTANT STATEMENT --- |
| PLEASE DO NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| 2)FL S S 713.13 |
| NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF |
| THE COURT. |
| NOTE: 713.13(2) |
| IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS |
| NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE |
| RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: |
| 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT |
| THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| |
| 3) WPB ADMIN CODE 106.3* PRODUCT |
| APPROVALS. THOSE PRODUCT WHICH ARE |
| REGULATED BY DCA RULE 9B-72 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| FOR JURISDICTIONAL APPROVAL. SUBMIT PRODUCT APPROVAL |
| FOR NEW ROLL-UP DOOR. |
| |
| 4)SHOW THE STRUCTURAL SUPPORT IN DETAIL WHERE THE |
| WALL WILL BE REMOVED AND THE ROLL-UP DOOR WILL BE |
| INSTALLED. |
| |
| 5)THE ARCHITECT SEAL SHALL BE CLEAR AND LEGIBLE ON |
| ALL SHEETS. SEE THE SEAL OF JOBY L. BALINT. HIS NAME IS |
| NOT LEGIBLE ON THE SEAL,F.S. 481.221(2). |
| |
| 6)THE DRAWINGS SHOWS TENANT 101 AND TENANT 103. WILL |
| THERE BE ONE TENANT OR TWO? INDICATE THE SQUARE FOOTAGE |
| OF EACH TENANT SPACE. THE DRAWINGS SHALL ALSO SHOW THE |
| SQUARE FOOTAGE OF THE STORAGE AND BUSINESS AREA. |
| |
| 7)THE MATERIALS AND PRODUCTS WHICH WILL BE STORED IN |
| THE STORAGE AREA SHALL BE INDICATED ON THE DRAWINGS SO |
| THAT THE CORRECT WALL AND FLOOR SEPERATIONS ARE |
| INSTALLED PER FBC. TABLE 302.3.2 AND FBC 708. |
| |
| |
| 8) 110.2* W. P. B. ADMINISTRATIVE |
| CODE, INFORMATION THAT IS REQUIRED FOR |
| RECORD KEEPING & FOR CERTIFICATE OF |
| OCCUPANCY: |
| A) THE EDITION OFTHE CODE UNDER WHICH |
| THE PERMIT WAS ISSUED. |
| B) THE USE AND OCCUPANCY, IN ACCORDANCE |
| WITH THE PROVISIONS OF CHAPTER 3. |
| C) THE TYPE OF CONSTRUCTION AS DEFINED |
| IN CHAPTER 6, TABLE 601. |
| D) THE DESIGN OCCUPANT LOAD, SEE 1004. |
| E) IF AN AUTOMATIC SPRINKLER SYSTEM IS |
| PROVIDED, WHETHER THE SPRINKLER SYSTEM |
| IS REQUIRED. |
| F) ANY SPECIAL STIPULATIONS & CONDITIONS |
| OF THE BUILDING PERMIT. |
| ------------------------------------- |
| ) NUMBER OF UNITS |
| ) NUMBER OF FLOORS |
| ) NUMBER OF ROOMS |
| ) SQ. FT. FOOTPRINT |
| ) SQ. FT. UNDER ROOF (TOTAL) |
| ) OCCUPANT LOAD |
| ) FLOOD ZONE |
| ) FLOOD ELEVATION |
| )L.O.M.R. |
| |
| 9)11-4.1.3 (12) STORAGE, SHELVING AND DISPLAY UNITS. |
| |
| (A) IF FIXED OR BUILT-IN STORAGE FACILITIES SUCH AS |
| CABINETS, SHELVES, CLOSETS, AND DRAWERS ARE PROVIDED IN |
| ACCESSIBLE SPACES, AT LEAST ONE OF EACH TYPE PROVIDED |
| SHALL CONTAIN STORAGE SPACE COMPLYING WITH SECTION |
| 11-4.25 . ADDITIONAL STORAGE MAY BE PROVIDED OUTSIDE OF |
| THE DIMENSIONS REQUIRED BY SECTION 11-4.25 . |
| (B)SHELVES OR DISPLAY UNITS ALLOWING SELF-SERVICE |
| BY CUSTOMERS IN MERCANTILE OCCUPANCIES SHALL BE LOCATED |
| ON AN ACCESSIBLE ROUTE COMPLYING WITH SECTION 11-4.3 . |
| REQUIREMENTS FOR ACCESSIBLE REACH RANGE DO NOT APPLY. |
| |
| 10)WHERE IS THE SECONDARY MEANS OF EGRESS? ONE SHOWS |
| SOME STAIRS, SO, HOW WILL THIS MEET THE ACCESSIBILITY |
| REQUIREMENTS.SEE SHEET AO.O2 |
| |
| 11)SHOW THE ELEVATION DRAWINGS OF THE DELIVERY AREA. |
| ARE THERE ANY ACCESSIBILE RAMPS? IF SO, INDICATE THE |
| SLOPE. |
| |
| |
| ) 106.1.2 ADDITIONAL DATA. THE |
| BUILDING OFFICIAL MAY REQUIRE DETAILS, COMPUTATIONS, |
| STRESS DIAGRAMS, AND OTHER |
| DATA NECESSARY TO DESCRIBE THE |
| CONSTRUCTION OR INSTALLATION AND THE |
| BASIS OF CALCULATION. ALL DRAWINGS, |
| SPECIFICATIONS AND ACCOMPANYING DATA |
| REQUIRED BY THE BUILDING OFFICIAL TO BE |
| PREPARED BY AN ARCHITECT OR ENGINEER |
| SHALL BE AFFIXED WITH THIER OFFICIAL |
| SEAL, SIGNATURE AND DATE AS STATE LAW |
| REQUIRES. THE DRAWINGS SHALL BE DIMENTIONED. SHOW ALL |
| THE DIMENTIONS OF ROOMS, CORRIDORS AND DOORS ETC. |
| |
| MYRON JACOBS |
| BUILDING PLAN REVIEWER |
| 805-6726 |
| |
| |
| |
| |
| |
| |