Plan Review Notes
Plan Review Notes For Permit 06120629
Permit Number 06120629
Review Stop B
Sequence Number 2
Notes
Date Text
2007-07-09 15:42:29DENIED BY BUILDING
  
 1) THE NOC THAT WAS SUBMITTED IS EXPIRED. IT WILL NEED
 TO BE RERECORDED BEFORE THE PERMIT IS ISSUED.
  
 2) SUBMIT A COPY OF THE PAID RECEIPT FOR THE COUNTY
 IMPACT FEES. ATTACH THE SHEETS WITH THE COUNTY IMPACT
 FEE STAMPS FROM THE OLD PLANS TO THE FRONT OF THE NEW
 PLANS OR HAVE THE NEW PLANS STAMPED BY THE COUNTY.
  
 3) THE ENERGY CALCULATION FORM IS REQUIRED TO BE SIGNED
 BY THE PREPARER PER FBC CHAPTER 13.
  
 4) BATHROOM DOOR NUMBER 10 ON THE SCHEDULE DOES NOT
 COMPLY WITH R322.1.1 FOR ACCESSIBILITY, WHICH REQUIRES
 AT LEAST ONE BATHROOM WITH A DOOR THAT HAS A 29" CLEAR
 OPENING.
 THE 29 " CLEAR OPENING IS WITH THE DOOR OPEN 90 DEGREES
 MEASURED BETWEEN THE FACE OF THE DOOR AND THE OPPOSITE
 STOP. SEE R322.2.2 AND FBC 11-4.13.5.
  
 5) THE TRUSS LAYOUT IS REQUIRED TO BE SIGNED, SEALED
 AND DATED BY THE TRUSS ENGINEER, IN ADDITION TO BEING
 REVIEWED AND APPROVED BY THE DESIGNER OF RECORD FOR THE
 STRUCTURE.
 FS 471
  
 6) THE TRUSS DRAWINGS ARE REQUIRED TO BE SIGNED BY THE
 TRUSS ENGINEER, SIGNATURE STAMPS ARE NOT ACCEPTABLE. FS
 471 AND FAC 61G15-23.002.
 NOTE: TRUSS LAYOUT AND DRAWINGS CAN BE SUBMITTED THE
 INSPECTOR IN THE FIELD AT TIME OF TRUSS INSPECTION.
  
 7) SPECIFY WHICH ONE OF THE FASTENING OPTIONS AND
 DESIGN PRESSURES ON PAGE 28 OF THE NOAWILL BE USED TO
 INSTALL THE GAF MODIFIED ROOF SYSTEM. CIRCLE THE
 APPROPRIATE ONE ON THE NOA. THE DESIGN PRESSURES ARE
 LESS THAN REQUIRED FOR A FLAT ROOF IN ZONE C ( -107.7
 PSF FOR ROOF ZONE 3 AND - 71.6 FOR ZONE 2) . SUBMIT RAS
 117 CALCULATIONS FOR ENHANCED FASTENING AS ALLOWED BY
 LIMITATION #7 ON PAGE 32 OF THE NOA.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714