2007-02-14 06:32:21 | DENIED BY BUILDING |
| |
| 1) THE NOC HAS EXPIRED. IT WILL BE REQUIRED TO HAVE IT |
| RERECORDED BEFORE THE PERMIT IS ISSUED. |
| |
| 2)SUBMIT ENERGY CALCULATIONS FOR THE NEW ADDITION AS |
| REQUIRED BY THE 2004 FBC CHAPTER 13. |
| |
| 3) SUBMIT A SITE PLAN SHOWING COMPLIANCE WITH R401.3 |
| DRAINAGE . |
| SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER |
| CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION SO AS |
| TO NOT CREATE A HAZARD. LOTS SHALL BE GRADED SO AS TO |
| DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE |
| GRADE AWAY FROM FOUNDATION WALLS SHALL FALL A MINIMUM |
| OF 6 INCHES (152 MM) WITHIN THE FIRST 10 FEET (3048 |
| MM). |
| EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER |
| PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL |
| WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE |
| PROVIDED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE |
| |
| 4) SHOW COMPLIANCE WITH R322.1.1 |
| ALL NEW SINGLE-FAMILY HOUSES, DUPLEXES, TRIPLEXES, |
| CONDOMINIUMS AND TOWNHOUSES SHALL PROVIDE AT LEAST ONE |
| BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE |
| BATHROOMS ARE PROVIDED ON HABITABLE GRADE LEVELS, WITH |
| A DOOR THAT HAS A 29-INCH (737 MM) CLEAR OPENING. |
| HOWEVER, IF ONLY A TOILET ROOM IS PROVIDED AT GRADE |
| LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF |
| NOT LESS THAN 29 INCHES (737 MM). ADDITIONS AND ALTERED |
| SPACES ARE REQUIRED TO COMPLY. SEE FBC CHAPTER 11. |
| |
| 5) SHOW COMPLIANCE WITH R807.1 ATTIC ACCESS. |
| IN BUILDINGS WITH COMBUSTIBLE CEILING OR ROOF |
| CONSTRUCTION, AN ATTIC ACCESS OPENING SHALL BE PROVIDED |
| TO ATTIC AREAS THAT EXCEED 30 SQUARE FEET (2.8 M 2 ) |
| AND HAVE A VERTICAL HEIGHT OF 30 INCHES (762 MM) OR |
| GREATER. |
| THE ROUGH-FRAMED OPENING SHALL NOT BE LESS THAN 22 |
| INCHES BY 30 INCHES (559 MM BY 762 MM) AND SHALL BE |
| LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE |
| LOCATION. A 30-INCH (762 MM) MINIMUM UNOBSTRUCTED |
| HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT SOME |
| POINT ABOVE THE ACCESS OPENING. SEE SECTION M1305.1.3 |
| FOR ACCESS REQUIREMENTS WHERE MECHANICAL EQUIPMENT IS |
| LOCATED IN ATTICS. |
| |
| 6) SPECIFY THE SIZE AND SPACING OF THE ROOF |
| VENTILATION. |
| R806.1 VENTILATION REQUIRED. |
| ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE |
| CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF |
| RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE |
| SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE |
| ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE |
| PROVIDED WITH CORROSION-RESISTANT WIRE MESH, WIT H 1 / |
| 8 INCH (3.2 MM) MINIMUM TO ? INCH (6.4 MM) MAXIMUM |
| OPENINGS. |
| R806.2 MINIMUM AREA. |
| THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS |
| THAN 1 TO 150 OF THE AREA OF THE SPACE VENTILATED |
| EXCEPT THAT THE TOTAL AREA IS PERMITTED TO BE REDUCED |
| TO 1 TO 300, PROVIDED AT LEAST 50 PERCENT AND NOT MORE |
| THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA IS |
| PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF |
| THE SPACE TO BE VENTILATED AT LEAST 3 FEET (914 MM) |
| ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE |
| REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. |
| AS AN ALTERNATIVE, THE NET FREE CROSS-VENTILATION AREA |
| MAY BE REDUCED TO 1 TO 300 WHEN A VAPOR BARRIER HAVING |
| A TRANSMISSION RATE NOT EXCEEDING 1 PERM (57.4 MG/S ? M |
| 2 ? PA) IS INSTALLED ON THE WARM SIDE OF THE CEILING. |
| |
| 7) BASED ON THE 2006 REVISIONS TO THE 2004 FBC WHICH |
| BECAME EFFECTIVE ON DECEMBER 8, 2006, THE STRUCTURE IS |
| LOCATED IN EXPOSURE CATEGORY C. PLEASE CORRECT ON SHEET |
| S1 AND ADJUST THE OPENING PRESSURES ACCORDINGLY. |
| |
| 8)ROOF SHEATHING IS REQUIRED TO BE IN ACCORDANCE WITH |
| SECTION R803.2.3.1 OF 2006 REVISIONS TO 2004 FBC |
| RESIDENTIAL CODE. WOOD STRUCTURAL PANEL SHEATHING SHALL |
| BE FASTENED TO ROOF FRAMING WITH 8D RING-SHANK NAILS AT |
| 6 INCHES ON CENTER AT EDGES AND 6 INCHES ON CENTER AT |
| INTERMEDIATE FRAMING. SPACING OF RING-SHANK FASTENERS |
| SHALL BE 4 INCHES ON CENTER IN NAILING ZONE 3 FOR 130 |
| MPH OR GREATER DESIGNWIND SPEEDS IN ACCORDANCE WITH |
| FIGURE R803.2.3.1. PLEASE SPECIFY ON THE PLANS. |
| |
| 9) SPECIFY THE ROOF SLOPE ON THE PLANS. TRUSS DRAWINGS |
| ARE FOR5/12 PITCH. |
| |
| 10) PROVIDE A FRAMING AND ATTACHMENT DETAIL FOR THE |
| ARCH AT THE COVERED ENTRY. |
| |
| 11)SPECIFY THE SIZES AND TYPE OF WINDOWS IN THE |
| EXISTING REAR BEDROOM. IF THE WINDOW THAT IS BEING IN |
| FILLED CONFORMS WITH EMERGENCY ESCAPE REQUIREMENTS OF |
| R310.1 OR IS LARGER THAN THE REMAINING ONE, THEN THE |
| REMAINING WINDOW WILL NEED TO BE CHANGED TO CONFORM. |
| EXISTING BUILDING CODE 501.2 CONFORMANCE. |
| AN EXISTING BUILDING OR PORTION THEREOF SHALL NOT BE |
| ALTERED SUCH THAT THE BUILDING BECOMES LESS SAFE OR |
| ENERGY EFFICIENT THAN ITS EXISTING CONDITION. IF IN THE |
| ALTERATION THE CURRENT LEVEL OF SAFETY OR SANITATION IS |
| TO BE REDUCED, THE PORTION ALTERED SHALL CONFORM TO THE |
| REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING . |
| |
| 12) THE TRUSS LAYOUT IS REQUIRED TO BE SIGNED, DATED |
| AND SEALED BY THE TRUSS ENGINEER. FS 471. THE DESIGNER |
| OF RECORD FOR THE STRUCTURE IS REQUIRED TO REVIEW AND |
| APPROVE THE TRUSS LAYOUT IN WRITING. |
| |
| 13) THE TRUSS DRAWINGS ARE REQUIRED TO HAVE THE |
| ORIGINAL SIGNATURE OF THE ENGINEER. SIGNATURE STAMPS |
| ARE NOT ACCEPTABLE. FS 471 AND FAC 61G15-23.002 |
| |
| 14) THE TRUSS LAYOUT AND DRAWINGS DO NOT CORRESPOND TO |
| THE ROOF FRAMING PLAN ON S1. THE ENTRY PORCH IS A GABLE |
| ON TRUSS DRAWINS AND A HIP ON THE PLANS. THE TRUSS |
| DRAWINGS SHOW THE TRUSSES STOPPING AT THE WALL OF THE |
| EXISTING STRUCTURE AND THE FRAMING PLAN SHOWS THEM |
| EXTENDING PAST THE WALL AND STRAPPED TO EXISTING |
| TRUSSES. PLEASE CORRECT. |
| |
| 15) THE STRAPPING SCHEDULE ON S1 INCORRECTLY SPECIFIES |
| (7) NAILS TO THE TRUSS FOR THE SIMPSON HTSM16. THE |
| CATALOG REQUIRES (8). |
| |
| 16)WPB ADMIN CODE 106.3* PRODUCT |
| APPROVALS. THOSE PRODUCT WHICH ARE |
| REGULATED BY DCA RULE 9B-72 SHALL BE |
| REVIEWED AND APPROVED IN WRITING BY THE |
| DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| FOR JURISDICTIONAL APPROVAL. |
| |
| 17) SUBMIT PRODUCT APPROVALS FOR THE SOLAR TUBE |
| SKYLIGHT. IMPACT PROTECTION REQUIRED. |
| |
| 18) SUBMIT PRODUCT APPROVALS FOR THE FLAT ROOF PORTION |
| OF THE ROOF. FROM THE PRODUCT APPROVAL SPECIFY THE |
| SYSTEM THAT WILL BE INSTALLED AND THE FASTENING OPTION |
| AND DESIGN PRESSURE THAT WILL BE USED. IF ENHANCED |
| FASTENING IS REQUIRED AT PERIMETER AND CORNERS, SUBMIT |
| RAS 117 CALCULATION. |
| |
| 19) SUBMIT THE UPDATED NOA FOR THE PGT FD101 FRENCH |
| DOOR. NOA 06-0807.07 HAS REVISED 02-0927.13. |
| |