2007-03-30 16:23:35 | BUILDING PLAN REVIEW |
| PERMIT: 06120320 |
| ADD: 222 LAKEVIEW AVE 3RD FLOOR |
| CONT: PASS INTERNATIONAL |
| TEL: (561)706-7201 |
| |
| |
| FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| W/ 2006 FBC REVISIONS |
| * WEST PALM BEACH AMENDMENTS |
| |
| 2NDREVIEW |
| ACTION: DENIED |
| |
| 1)--- VERY IMPORTANT STATEMENT --- |
| PLEASE DO NOT IGNORE! |
| WHEN RESUBMITTING PLANS PLEASE INDICATE |
| THE REVISION & REMOVE & REPLACE ANY |
| PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| BER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| TION PAGE WHERE THE CHANGES CAN BE FOUND |
| WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| 2 ) FL S S 713.13 |
| NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF |
| THE COURT. |
| NOTE: 713.13(2) |
| IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS |
| NOT ACTUALLYCOMMENCED |
| WITHIN 90 DAYS AFTER THE RECORDING THEREOF, SUCH NOTICE |
| IS NULL & VOID. |
| NOTE: 713.13(6)THE POSTING OF THE NOTICE OF |
| COMMENCEMENT AT THE |
| CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. |
| |
| 3A)2ND REQUEST, THE MEP, FA AND FS SHEETS ARE STILL |
| MISSING THE CERTIFICATE OF AUTHORIZATION FOR ASSOCIATED |
| SPACE DESIGN. |
| 481.219 F.S.CERTIFICATE OF |
| AUTHORIZATION.THE TITLE BLOCK FOR ANY |
| SHEET BEARING THE NAME OF AN ARCHITECT |
| PRACTICING UNDER A FICTITIOUS NAME, A |
| CORPORATION, OR A PARTNERSHIP, OFFERING ARCHITECTURAL |
| SERVICES, SHALL INCLUDE |
| THE CERTIFICATE OF AUTHORIZATION |
| NUMBER.ADD THE NUMBER TO EACH SHEET. |
| THIS MAY BE ADDED BY HAND. |
| |
| 3 B-C)OK |
| |
| 3D) 2ND REQUEST, BUILDING FEATURES, TYPE OF |
| CONSTRUCTION, TYPE I UNPROTECTED, SPRINKLERED. PLEASE |
| SEE |
| TABLE 503, TYPE I BUILDINGS ARE EITHER AOR B FOR |
| ALLOWABLE STORIES. RESPONCE WAS WE ARE NOT ADDING ANY |
| STORIES. |
| WHILE THIS IS TRUE NO STORIES ARE BEING ADDED THE |
| AMOUNT OF FIRE SAFING BUILT INTO THE BUILDING IS |
| DETERMINED IF THE BUILDING EXCEEDS A CERTIAN LIMIT IN |
| FT. TABLE 503 |
| WHILW A TYPE IB BUILDING IS LIMITED TO 160' A TYPE IA |
| BUILDING IS UNLIMITED IN HEIGTH. TABLE 601 PROVIDES THE |
| DIFFERENCE IN FIRE RATINGS BETWEEN A TYPE IA OR A IB. |
| PLEASE PROVIDE FOOTAGE IN HEIGTH, SO THE CORRECT FIRE |
| SAFING REQUIREMENTS WILL BE MEET IN THE NEW FLOOR DECK |
| AREA. |
| |
| 4)2ND REQUEST,A7.041 DETAIL# 1 PANTRY, THE |
| ELEVATIONS FAIL TO SHOW COMPLIANCE |
| FOR A FORWARD APPROACH. THE DOORS FLOORAND SHELVING |
| WOULD NEED TO BE REMOVED |
| TO ALLOW FOR THE FORWARD APPROACH USAGE. |
| T SINKS: |
| 11-4.24.2 SINKS, HEIGHT. SINKS SHALL |
| BE MOUNTED WITH THE COUNTER NO HIGHER |
| THAN 34" ABOVE THE FINISH FLOOR. |
| 11-4.24.3 KNEE CLEARANCE THAT IS AT |
| LEAST 27" HIGH 30" WIDE, AND 19" DEEP |
| SHALL BE PROVIDED UNDERNEATH SINKS. |
| 11-4.24.5 CLEAR FLOOR SPACE. |
| A CLEAR FLOOR SPACE AT LEAST 30 INCHES BY 48 INCHES |
| (760 MM BY 1219 MM) COMPLYING WITH |
| SECTION 11-4.2.4 SHALL BE PROVIDED IN FRONT OF A SINK |
| TO ALLOW FORWARD APPROACH. THE CLEAR |
| FLOOR SPACE SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL |
| EXTEND A MAXIMUM OF 19 INCHES (485 MM) UNDERNEATH THE |
| SINK. |
| |
| 5) 2ND REQUEST NUMBER (7) FROM THE PREVIOUS REVIEW, THE |
| WORK TO BE INCLUDED IN THIS PERMIT , ADDITIONAL JOIST |
| 4TH FLOOR WILL REQUIRE A THRESHOLD INSPECTOR ONSITE |
| DURING THIS PORTION OF WORK. |
| WPB AMENDMENT 105.13.6. W.P.B. |
| CONSTRUCTION SERVICES DEPARTMENT |
| REQUEST FOR THRESHOLD BUILDINGS A |
| SPECIAL INSPECTOR AS REQUIRED BY S. |
| 553.79(5) FLORIDA STATUTES TO THE MIN- |
| IMUM INSPECTIONS REQUIRED BY THIS CODE. |
| CONTACT HAROLD PISKURA MANAGER OF THE |
| SPECIAL INSPECTOR PROGRAM AT (561) |
| 805-6711 FOR FURTHER INFORMATION BEFORE |
| THE PERMIT MAY BE ISSUED. |
| |
| 6) THE THRESHOLD INSPECTION PLAN HAS A STAMPED |
| SIGNATURE NOT AH ORIGINAL. PLANS, SPECIFICATIONS, |
| REPORTS OR |
| OTHER DOCUMENTS PREPARED BY THE DESIGN PROFESSIONAL AND |
| BEING FILED FOR PUBLIC |
| RECORD SHALL HAVE THE SIGNATURE AND |
| SEAL OF THE DESIGN PROFESSIONAL AFFIXED |
| TO THE DOCUMENT. |
| FL STATE STAT: 61G15-23.002 ENGINEERS |
| FL ATATE STAT: 61G16.003 ARCHITECTS |
| |
| NOTE: 3 SETS OF THE THRESHOLD INSPECTION PLAN WILL BE |
| RQUIRED AS WELL ASSETS OF PLANS, "THRESHOLD |
| BUILDING". |
| |