Plan Review Notes For Permit 06120107 |
Permit Number |
06120107 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2007-01-03 10:04:49 | BUILDING PLAN REVIEW | | PERMIT:06120107 | | ADD:580 VILLAGE BLVD #380 | | CONT: G.A. RAY INC. | | TEL: (561)630-4861 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW 1ST | | ACTION: DENIED | | | | 1)THE CLAIMED VALUATION ON THE APPLICATION IS LOW. | | FOR PERMITTING PURPOSES VALUATION OF BUILDING AND | | SYSTEMS SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE | | STRUCTURAL ELECTRIC, PLUMBING, MECHINICAL, INTERIOR | | FINISH, ARCHITECTURAL AND DESIGN FEES MARKETING COSTS, | | OVERHEAN AND PROFIT EXCLUDING LAND VALUE. OUR VALUATION | | REFERENCE IS ICC (BVD), MARSHALL-SWIFT AND MEANS COSTS | | ANALYSIS. FBC.108.3* | | | | 2) 110.2* W. P. B. ADMINISTRATIVE | | CODE, INFORMATION THAT IS REQUIRED FOR | | RECORD KEEPING & FOR CERTIFICATE OF | | OCCUPANCY: | | A) THE EDITION OFTHE CODE UNDER WHICH | | THE PERMIT WAS ISSUED. | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | WITH THE PROVISIONS OF CHAPTER 3. | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | IN CHAPTER 6, TABLE 601. | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | ----------------------------------- | | ) SQ. FT. FOOTPRINT | | ) SQ. FT. UNDER ROOF (TOTAL) | | ) OCCUPANT LOAD | | | | 3) 11-4.24.5 SHOW THE CLEAR FLOOR SPACE ON THE FLOOR | | PLAN. A CLEAR FLOOR SPACE AT LEAST 30 INCHES BY 48 | | INCHESCOMPLYING WITH SECTION 11-4.2.4 SHALL BE PROVIDED | | IN FRONT OF A SINK TO ALLOW FORWARD APPROACH. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 | | | | |
|