Plan Review Notes For Permit 06110857
Permit Number 06110857
Review Stop M
Sequence Number 1
Notes
Date Text
2006-12-08 11:37:00*** DENIED ***
 1) ENERGY CALCULATIONS ARE SHOWING THE WRONG
 JURISDICTION NUMBER, PLEASE CORRECT.
  
 2) ENERGY CAL'S. ARE CALLING FOR A HEAT PUMP UNIT,
 PLANS ARE CALLING FOR A STRAIGHT COOLING UNIT WITH
 ELECTRIC HEAT, PLEASE CORRECT ENERGY CAL'S.
  
 3) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT
 ALSO, PER 2004 FBC 13-600.3.ABC.2.
  
 4) PLEASE SUBMIT A COMPLETE ENERGY CALCULATION NOT JUST
 THE FRONT PAGE.
  
 5) PLEASESUBMITMANUAL J CALCULATIONS, PER 2004 FBC
 13-607.1.ABC.1 .
  
 6) SHOW THE LOCATION OF THE CLOTHES DRYER VENT
 TERMINATION ON THE MECH. PLANS, BE AWARE THE VENT MAY
 NOT TERMINATE NEAR THE A/C CONDENSER UNIT, PER 2004
 FBC/M 501.2 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.